F
AULT
M
ESSAGES
, P
OWER
G
EN
115
1009
Burner blower RPM out of range During startup, blower RPM readings are
outside the thresholds.
Power disconnect switch in OFF position,
low battery charge or damaged battery,
blower not programmed to speed mode
(<PG153), incorrect blower setting, blocked
filter or exhaust, damaged blower, blower
wiring issue, problem with auxiliary
power, aux power not setup correctly.
• Verify power disconnect switch is in
“1” position
• Measure battery voltage >12V during
startup
• Power cycle QEC
• Check fuses on FPC
• Measure 220V at aux input to FPC
• Check wiring to blower for loose pins
• Verify FPC configured to correct
blower
• Verify Fasco blower has updated
settings
• Verify Aux power is set to
220VAC/>7Amps
1011
Invalid pump feedback reading
Feedback value of the pump does not
represent a normal running range or a
known pump fault code. It can also occur
when the pump is not in standby (95%)
when initially powering it on.
FEB 12V/24V jumper set incorrectly, low
battery voltage (<12v), noise on pump
wiring, bad pump signal wiring, bad pump
electronics, bad FPC or FEB hardware, low
voltage to FPC, pump located in HRU. If
feedback 0% and flow rate above 10lpm,
bad pump control board, feedback
harness or FPC. Pump feedback value is
90% fault/blocked pump, 85% electrical
supply fault, 75% warning. Review Fault
2016 and Fault 2017.
Table 15-2 PowerGen Error Messages, Service Required
Fault Code
Description
Possible Causes
Summary of Contents for PowerGen 5650 Series
Page 1: ...7045 102089 000 June 1 2021 Installation Operation Manual FOR A QUALIFIED INSTALLER...
Page 8: ...iv...
Page 12: ...iv Figure 21 9 ATS Enclosure 179 Figure 21 10 Battery Connection Schematic 181...
Page 28: ...SYSTEM INTRODUCTION 16 Figure 3 6 P ID Diagram...
Page 69: ...QNERGY LYNX SOFTWARE 57 Figure 6 57 FPC FEB QEC Firmware Update...
Page 158: ...MAINTENANCE 146 Figure 17 2 Radiator and Over Flow Tank...
Page 194: ...POWERGEN OPTIONAL FEATURE SETS 182...