Figure 6-8 FDC, Data, Hall Sensor
Table 6-6 FPC, Data, Hall Sensor
Control/Indication
Description
Amplitude
A number between 0 and 15 coarsely approximating peak converter
amplitude (0 = Minimal stroke; 15 = Maximal stroke), (mm)
Offset
Engine piston bias (mm)
Frequency
Engine piston frequency (Hz)
Phase
Internal value resembling the phase difference between the measured
hall sensor signals and the estimated piston waveform (
?
)
Quality
Quality of piston waveform estimation (%)