C
OMMISSIONING
P
ROCEDURE
76
12.5 HELIUM FILL
This procedure fills the Free-Piston Stirling Engine with helium. It uses a fill kit
(5000-103913-000) which is shown in Figure 12-4 on 74.
WARNING:
High Pressure Gas Vessel!
Before performing the helium fill:
-Make sure the tank and vent valves are closed.
-Fully open the regulator to its lowest pressure
setting.
-Make sure the tank is firmly secured.
-If the helium fill line was removed during storage,
reattach it securely.
-At no circumstance shall the engine be charged
above 60bar.
-Wear safety glasses during engine helium fill
procedure.
-Use only >99.99% purity helium (UN1046 or
greater).
WARNING:
Qnergy Engines use helium gas under
high pressure. Never hammer, weld, or drill on any
part of the engine.
Never transport the engine while filled with
greater than 2 bar (30 PSI) of helium.
Vent helium completely before disposal.
Contact Qnergy Customer Support to request
QB80 engine decommissioning procedure
document.
CAUTION:
The helium fill must be performed by a
suitably qualified technician with local regulations.
Perform this procedure only when the system is
disabled and the engine is at ambient
temperature.
Summary of Contents for PowerGen 5650 Series
Page 1: ...7045 102089 000 June 1 2021 Installation Operation Manual FOR A QUALIFIED INSTALLER...
Page 8: ...iv...
Page 12: ...iv Figure 21 9 ATS Enclosure 179 Figure 21 10 Battery Connection Schematic 181...
Page 28: ...SYSTEM INTRODUCTION 16 Figure 3 6 P ID Diagram...
Page 69: ...QNERGY LYNX SOFTWARE 57 Figure 6 57 FPC FEB QEC Firmware Update...
Page 158: ...MAINTENANCE 146 Figure 17 2 Radiator and Over Flow Tank...
Page 194: ...POWERGEN OPTIONAL FEATURE SETS 182...