F
AULT
M
ESSAGES
, P
OWER
G
EN
122
2026
Cooling capacity insufficient
Fouled radiator on air side,
seized HRU fan or failed fan,
insufficient coolant, HRU panel
left open, incorrect fan type
configured, windy conditions.
• Verify all panels secured
in place.
• Verify both fans are
operating.
• Verify coolant in radiator
is topped off.
• Clean radiator.
• Verify correct fan type
configured.
2027
Disconnect switch open
Move disconnect switch to the
‘1’ position
Table 15-4 PowerGen Error Messages, Auto Reset
Fault Code
Description
Possible Causes
3003
No gas
Gas pressure insufficient,
damaged pressure sensor,
PowerGen will activate
automatically once pressure
increases above 15mbar. There
is no timeout on this state.
• Check all gas supply
valves are open.
• Liquids freezing up at
pressure cuts, heat trace
and insulate piping 10ft
upstream of regulators.
3004
Gas conditioning unit liquid
level too high
Liquids must be drained
before PowerGen can
continue to operate. Stuck or
damaged upper level sensor,
open wiring.
Table 15-3 PowerGen Error Messages, User Clearable
Fault Code
Description
Possible Causes
Summary of Contents for PowerGen 5650 Series
Page 1: ...7045 102089 000 June 1 2021 Installation Operation Manual FOR A QUALIFIED INSTALLER...
Page 8: ...iv...
Page 12: ...iv Figure 21 9 ATS Enclosure 179 Figure 21 10 Battery Connection Schematic 181...
Page 28: ...SYSTEM INTRODUCTION 16 Figure 3 6 P ID Diagram...
Page 69: ...QNERGY LYNX SOFTWARE 57 Figure 6 57 FPC FEB QEC Firmware Update...
Page 158: ...MAINTENANCE 146 Figure 17 2 Radiator and Over Flow Tank...
Page 194: ...POWERGEN OPTIONAL FEATURE SETS 182...