F
AULT
M
ESSAGES
, P
OWER
G
EN
124
4008
‘Engine Bay 2’ temp sensor
failed
Sensor failed open or short
circuit, bad wiring.
• Inspect the channel NTC2
on the FPC is connected
• Inspect connector and
cable for damage.
• Replace sensor.
4009
‘Eng. Bay Bottom’ temp sensor
failed
Sensor failed open or short
circuit, bad wiring.
• Inspect the channel NTC3
on the FPC is seated well.
• Inspect connector and
cable for damage.
• Replace sensor.
4010
‘HRU Top’ temp sensor failed
Sensor failed open or short
circuit, bad wiring.
• Inspect the channel
P10-HRU SENSORS on the
FEB is seated well.
• Check Jumper cable X__ is
seated well between the
FEB and FPC.
• Inspect sensor connector
and cable for damage.
• Replace sensor.
Table 15-5 PowerGen Error Messages, Warning
Fault Code
Description
Possible Causes