Figure 12-19 Qnergy Lynx, Output Power Limit to 600W
NOTE: The #2 screw has a cover (plug) that must be removed prior to turning the screw.
15. To decrease Lambda, turn screw #2 clockwise (see Figure 12-13 on page 84)
.
16.To
increase
Lambda, turn screw #2
counter-clockwise
(see Figure 12-13 on page 84).
17.Repeat steps #6 through #16 until the gas regulator is tuned correctly.
18.Verify head temperature is 600°C
12.8 GAS VALVE TUNING, POWERGEN 600, 1200, 1800 (LOW TEMP SYSTEMS INCLUDED)
NOTE: Chapter 12.8 is for tuning a PowerGen 600, 1200, 1800 (Low Temp systems included)
only.