F
AULT
M
ESSAGES
, P
OWER
G
EN
137
12006
Engine running detected while
QEC is disabled
QEC hardware failure
12007
E-stop is active
Internal E-stop triggered.
12V supply to FEB pulled low,
check battery voltage above
12V during startup, check loads
on 12V supply to FEB (gas
valve heater, etc.)
12008
Low battery
• Low battery
• 12V power leads are not
securely tied to battery
post.
• Not enough power
available for auxiliary
loads and charging the
battery.
• Faulty battery
12010
Battery needs service
Faulty battery - replace
12014
Engine current too high
Heat source provides too
much heat
12015
QEC too hot to start
Problems in cooling system
that have caused the QEC to
overheat.
• Check cooling system for
issues or blockages.
• Wait for system to cool
down and try again.
13001
Coolant temperature too high
• Auxiliary output off
• Temperature sensor bad
• Coolant leak
• Pump failure
Table 15-8 QEC Error Messages, QEC 3.5 (Firmware 3.X.X)