F
AULT
M
ESSAGES
, P
OWER
G
EN
123
Table 15-5 PowerGen Error Messages, Warning
Fault Code
Description
Possible Causes
4003
External E-Stop signal was
activated on orange terminal
The customer E-Stop circuit
was opened by a safety device
disabling the unit, low battery
voltage.
4004
CAN node ID is out of range
Illegal CAN node ID has been
sent by an external command.
4005
Gas supply problem detected
While blower is increasing
estimated head temperature
is not increasing as expected.
• Gas pressure low (FPC FW
below 1.9.0).
• Bad gas quality
• Incorrect gas valve
calibration.
• HHT offset incorrect
(actual and estimated
more than 100°C apart
from each other).
• Aux power foldback,
blower is shutting off.
• Fan harness does not
have PTC (QEC FW 2.x.x +
Dunli fans only).
• Blower max set too low
(QEC FW 3.1.0+)
• Damaged BCU.
4007
‘Engine Bay 1’ temp sensor
failed
Sensor failed open or short
circuit, bad wiring.
• Inspect the channel NTC1
on the FPC is connected
• Inspect connector and
cable for damage.
• Replace sensor.
Summary of Contents for PowerGen 5650 Series
Page 1: ...7045 102089 000 June 1 2021 Installation Operation Manual FOR A QUALIFIED INSTALLER...
Page 8: ...iv...
Page 12: ...iv Figure 21 9 ATS Enclosure 179 Figure 21 10 Battery Connection Schematic 181...
Page 28: ...SYSTEM INTRODUCTION 16 Figure 3 6 P ID Diagram...
Page 69: ...QNERGY LYNX SOFTWARE 57 Figure 6 57 FPC FEB QEC Firmware Update...
Page 158: ...MAINTENANCE 146 Figure 17 2 Radiator and Over Flow Tank...
Page 194: ...POWERGEN OPTIONAL FEATURE SETS 182...