63
Specifications
Section 2-2
Output Terminal Block (Bottom Block)
Setting Functions Using Instructions and PLC Setup
I/O Terminal Blocks of CPU Units with 10 I/O Points
Input Terminal Block (Top Block)
Setting Input Functions Using PLC Setup
Address
When the
instructions to
the right are not
executed
When a pulse output
instruction (SPED, ACC,
PLS2, or ORG) is executed
When origin searches are
enabled in PLC Setup, and an
origin search is executed with
ORG instruction
When the PWM
instruction is
executed
Word
Bit
Normal outputs
Fixed duty ratio pulse output
Variable duty ratio
pulse output
CW/CCW
Pulse plus
direction
+ When the origin search
function is used
PWM output
CIO 100 00
Normal output 0
Pulse output
0 (CW)
Pulse output
0 (pulse)
---
---
01
Normal output 1
Pulse output
0 (CCW)
Pulse output
0 (direction)
---
PWM output 0
02
Normal output 2
Pulse output
1 (CW)
Pulse output
1 (pulse)
---
---
03
Normal output 3
Pulse output
1 (CCW)
Pulse output
1 (direction)
---
PWM output 1
04
Normal output 4
---
---
Origin search 0 (Error counter
reset output)
---
05
Normal output 5
---
---
Origin search 1 (Error counter
reset output)
---
Address
Input operation settings
High-speed counters
Origin searches
Word
Bit
Normal
inputs
Interrupt
inputs
(See note.)
Quick-
response
inputs
Operation settings:
High-speed counters enabled
Phase-Z reset
Origin searches
enabled for pulse
outputs 0
Single-phase
(increment
pulse input)
Two-phase (differential
phase x4, up/down, or
pulse/direction)
CIO 0
00
Normal
input 0
---
---
Counter 0, incre-
ment input
Counter 0, A phase, up,
or count input
---
01
Normal
input 1
---
---
Counter 1, incre-
ment input
Counter 0, B phase,
down, or direction input
---
02
Normal
input 2
---
---
Counter 2, incre-
ment input
Counter 1, A phase, up,
or count input
---
03
Normal
input 3
---
---
Counter 3, incre-
ment input
Counter 1, B phase,
down, or direction input
Pulse output 0: Ori-
gin proximity input
signal
04
Normal
input 4
Interrupt
input 0
Quick-
response
input 0
Counter 0,
phase-Z/reset
input
Counter 0, phase-Z or
reset input
---
05
Normal
input 5
Interrupt
input 1
Quick-
response
input 1
Counter 1,
phase-Z reset
input
Counter 1, phase-Z or
reset input
Pulse output 0: Ori-
gin input signal
COM
05
AC Power Supply Models
DC Power Supply Models
COM
+
−
NC
CIO 100
NC
COM
COM
03
COM
CIO 100
COM
COM
01
04
00
02
COM
03
05
01
04
00
02
NC
NC
NC
NC
L1
L2/N COM
01
03
05
00
02
04
AC Power Supply Models
Inputs (CIO 0)
DC Power Supply Models
COM
01
03
05
00
02
04
+
−
NC
Inputs (CIO 0)
Summary of Contents for CP1L CPU UNIT - 03-2009
Page 1: ...Cat No W462 E1 06 CP1L CPU Unit SYSMAC CP Series CP1L L_0D_ CP1L M_0D_ OPERATION MANUAL...
Page 2: ......
Page 4: ...iv...
Page 10: ...x...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 70: ...36 Function Blocks Section 1 5...
Page 584: ...550 Trouble Shooting Section 8 7...
Page 627: ...593 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 630: ...596 Sample Application Section 9 12...
Page 654: ...620 Troubleshooting Unit Errors Section 11 4...
Page 662: ...628 Replacing User serviceable Parts Section 12 2...
Page 668: ...634 Standard Models Appendix A...
Page 698: ...664 Auxiliary Area Allocations by Function Appendix C...
Page 746: ...712 Auxiliary Area Allocations by Address Appendix D...
Page 773: ...739 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 774: ...740 Connections to Serial Communications Option Boards Appendix F...
Page 806: ...772 Index...
Page 808: ...774 Revision History...