207
Pulse Outputs
Section 5-2
CW Limit Input Signal Flags
This is the CW limit input signal, which is used in the
origin search.
ON when turned ON from an external
input.
A540.08
A541.08
CCW Limit Input Signal Flags
This is the CCW limit input signal, which is used in
the origin search.
ON when turned ON from an external
input.
A540.09
A541.09
Positioning completed input signals
This is the positioning completed input signal, which
is used in the origin search.
ON when turned ON from an external
input.
A540.10
A541.10
Accel/Decel Flags
ON when pulses are being output according to an
ACC(888) or PLS2(887) instruction and the output
frequency is being changed in steps (accelerating or
decelerating).
0: Constant speed
1: Accelerating or decelerating
A280.00
A281.00
Overflow/Underflow Flags
ON when an overflow or underflow has occurred in
the pulse output PV.
0: Normal
1: Overflow or underflow
A280.01
A281.01
Output Amount Set Flags
ON when the number of output pulses has been set
with the PULS instruction.
0: No setting
1: Setting made
A280.02
A281.02
Output Completed Flags
ON when the number of output pulses set with the
PULS(886)/PLS2(887) instruction has been output.
0: Output not completed.
1: Output completed.
A280.03
A281.03
Output In-progress Flags
ON when pulses are being output from the pulse
output.
0: Stopped
1: Outputting pulses.
A280.04
A281.04
No-origin Flags
ON when the origin has not been determined for the
pulse output.
0: Origin established.
1: Origin not established.
A280.05
A281.05
At-origin Flags
ON when the pulse output PV matches the origin
(0).
0: Not stopped at origin.
1: Stopped at origin.
A280.06
A281.06
Output Stopped Error Flags
ON when an error occurred while outputting pulses
in the origin search function.
0: No error
1: Stop error occurred.
A280.07
A281.07
Stop Error Codes
When a Pulse Output Stop Error occurs, the error
code is stored in that pulse outputs corresponding
Stop Error Code word.
---
A444
A445
Function
Pulse output number
0
1
Summary of Contents for CP1L CPU UNIT - 03-2009
Page 1: ...Cat No W462 E1 06 CP1L CPU Unit SYSMAC CP Series CP1L L_0D_ CP1L M_0D_ OPERATION MANUAL...
Page 2: ......
Page 4: ...iv...
Page 10: ...x...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 70: ...36 Function Blocks Section 1 5...
Page 584: ...550 Trouble Shooting Section 8 7...
Page 627: ...593 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 630: ...596 Sample Application Section 9 12...
Page 654: ...620 Troubleshooting Unit Errors Section 11 4...
Page 662: ...628 Replacing User serviceable Parts Section 12 2...
Page 668: ...634 Standard Models Appendix A...
Page 698: ...664 Auxiliary Area Allocations by Function Appendix C...
Page 746: ...712 Auxiliary Area Allocations by Address Appendix D...
Page 773: ...739 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 774: ...740 Connections to Serial Communications Option Boards Appendix F...
Page 806: ...772 Index...
Page 808: ...774 Revision History...