11
Features and Main Functions
Section 1-1
Note
For each input, a PLC Setup parameter determines whether it is to be used as
a normal input, interrupt input, quick-response input, or high-speed counter.
Analog Settings
Changing Settings Using
Analog Adjustment
By adjusting the analog adjuster with a Phillips screwdriver, the value in the
Auxiliary Area can be changed to any value between 0 and 255. This makes it
easy to change set values such as timers and counters without Programming
Devices.
Changing Settings Using
External Analog Setting
Inputs
External analog values of 0 to 10 V (resolution: 256) are converted to digital
values and stored in a word in the AR Area. This enables applications that
require on-site adjustment of settings that do not demand a particularly high
degree of accuracy, such as for example, a setting based on changes in out-
door temperatures or potentiometer inputs.
Phillips screwdriver
Analog adjuster
Ladder program
Example: The production quantity could be changed by
changing the counter set value from 100 to 150.
Turning the control on the CP1H changes the
PV in A642 between 0000 and 0255 (00 and
FF hex).
CNTX
A642
External analog setting
input connector
Ladder program
Example: The production quantity could be changed by changing
the timer set value from 100 to 150.
When a voltage (0 to 10 V) is input from a
device such as a potentiometer to the
external analog setting input, the PV in A643
is refreshed between 0000 and 0100 hex (0
to 256).
TIMX
A643
0 to 10 V
Potentiometer, temperature
sensor, etc.
Summary of Contents for CP1L CPU UNIT - 03-2009
Page 1: ...Cat No W462 E1 06 CP1L CPU Unit SYSMAC CP Series CP1L L_0D_ CP1L M_0D_ OPERATION MANUAL...
Page 2: ......
Page 4: ...iv...
Page 10: ...x...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 70: ...36 Function Blocks Section 1 5...
Page 584: ...550 Trouble Shooting Section 8 7...
Page 627: ...593 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 630: ...596 Sample Application Section 9 12...
Page 654: ...620 Troubleshooting Unit Errors Section 11 4...
Page 662: ...628 Replacing User serviceable Parts Section 12 2...
Page 668: ...634 Standard Models Appendix A...
Page 698: ...664 Auxiliary Area Allocations by Function Appendix C...
Page 746: ...712 Auxiliary Area Allocations by Address Appendix D...
Page 773: ...739 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 774: ...740 Connections to Serial Communications Option Boards Appendix F...
Page 806: ...772 Index...
Page 808: ...774 Revision History...