![background image](http://html1.mh-extra.com/html/omron/cp1l-cpu-unit-03-2009/cp1l-cpu-unit-03-2009_operation-manual_742084704.webp)
670
Auxiliary Area Allocations by Address
Appendix D
A36
07
Error Counter
Alarm Flag 1
This flag turns ON when an alarm
occurs in the error counter for
inverter positioning 1.
ON: Error
counter alarm
OFF: No error
counter alarm
---
Cleared
When
pulse out-
put to error
counter is
stopped
and abso-
lute value
of error
counter
present
value is
greater
than or
equal to
error
counter
alarm
detection
value
---
15
Inverter Posi-
tioning Output
Value Sign
Flag 1
This flag is ON when the inverter
positioning 1 output value is positive
and is OFF when it is negative.
ON: Positive
value
OFF: Nega-
tive value
---
Cleared
When
signed out-
put value is
between
FFFF
FFFF and
8000 0000
---
A38
and
A39
Present Value
of Pulse Out-
put to Inverter
1, Relative
Value
These words contain the relative
value of the internal pulse output
when pulses are being output to the
error counter for inverter positioning
1.
Data range: 8000 0000 to 7FFF
FFFF hex (
−
2,147,483,648 to
2,147,483,647)
A38 contains the leftmost 4 digits
and A39 contains the rightmost 4
digits.
---
---
Cleared
Every error
counter 1
cycle
---
A90 to
A93
All
User Program
Date
These words contain in BCD the
date and time that the user program
was last overwritten.
A90.00 to A90.07:
Seconds (00 to 59)
A90.08 to A90.15:
Minutes (00 to 59)
A91.00 to A91.07: Hour (00 to 23)
A91.08 to A91.15:
Day of month (01 to 31)
A92.00 to A92.07: Month (01 to 12)
A92.08 to A92.15: Year (00 to 99)
A93.00 to A93.07: Day of the week
(00: Sunday, 01: Monday, 02: Tues-
day, 03: Wednesday, 04: Thursday,
05: Friday, 06: Saturday)
---
Retained
Retained ---
---
A94 to
A97
All
Parameter
Date
These words contain in BCD the
date and time that the parameters
were last overwritten.
The format is the same as above.
---
Retained
Retained ---
---
Address
Name
Function
Settings
Status
after
mode
change
Status
at star-
tup
Write
timing
Related
flags, set-
tings
Words
Bits
Summary of Contents for CP1L CPU UNIT - 03-2009
Page 1: ...Cat No W462 E1 06 CP1L CPU Unit SYSMAC CP Series CP1L L_0D_ CP1L M_0D_ OPERATION MANUAL...
Page 2: ......
Page 4: ...iv...
Page 10: ...x...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 70: ...36 Function Blocks Section 1 5...
Page 584: ...550 Trouble Shooting Section 8 7...
Page 627: ...593 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 630: ...596 Sample Application Section 9 12...
Page 654: ...620 Troubleshooting Unit Errors Section 11 4...
Page 662: ...628 Replacing User serviceable Parts Section 12 2...
Page 668: ...634 Standard Models Appendix A...
Page 698: ...664 Auxiliary Area Allocations by Function Appendix C...
Page 746: ...712 Auxiliary Area Allocations by Address Appendix D...
Page 773: ...739 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 774: ...740 Connections to Serial Communications Option Boards Appendix F...
Page 806: ...772 Index...
Page 808: ...774 Revision History...