702
Auxiliary Area Allocations by Address
Appendix D
A598
A598.00 FPD Teach-
ing Bit
Turn this bit ON to set the monitoring
time automatically with the teaching
function.
While A598.00 is ON, FPD(269)
measures how long it takes for the
diagnostic output to go ON after the
execution condition goes ON. If the
measured time exceeds the monitor-
ing time, the measured time is multi-
plied by 1.5 and that value is stored
as the new monitoring time.
(The teaching function can be used
only when a word address has been
specified for the monitoring time
operand.)
ON: Teach
monitoring time
OFF: Teaching
function OFF
Cleared
Cleared
---
---
A600 to
A603
All
Macro Area
Input Words
Before the subroutine specified in
MCRO(099) is executed, the source
words for the subroutine are trans-
ferred to A600 through A603 (input
parameter words).
Input data:
4 words
Cleared
Cleared
---
---
A604 to
A607
All
Macro Area
Output
Words
After the subroutine specified in
MCRO(099) has been executed, the
results of the subroutine are trans-
ferred from A604 through A607 to
the specified destination words (out-
put parameter words).
Output data:
4 words
Cleared
Cleared
---
---
A619
A619.01 Serial Port 1
Settings
Changing
Flag (CP1L
M-type CPU
Units)
ON while the serial port 1’s commu-
nications settings are being changed
for a CP1L M-type CPU Unit. This
flag will be turned ON when
STUP(237) is executed and it will be
turned OFF after the settings have
been changed.
ON: Changing
OFF: Not
changing
Retained
Cleared
---
---
A619.02 Serial Port 2
Settings
Changing
Flag (CP1L
M-type CPU
Units)
ON while the serial port 2’s commu-
nications settings are being changed
for a CP1L M-type CPU Unit. This
flag will be turned ON when
STUP(237) is executed and it will be
turned OFF after the settings have
been changed.
ON: Changing
OFF: Not
changing
Retained
Cleared
---
---
Serial Port 1
Settings
Changing
Flag (CP1L
L-type CPU
Units)
ON while the serial port 1’s commu-
nications settings are being changed
for a CP1L L-type CPU Unit. This
flag will be turned ON when
STUP(237) is executed and it will be
turned OFF after the settings have
been changed.
Addresses
Name
Function
Settings
Status
after
mode
change
Status at
startup
Write
timing
Related
Flags,
Settings
Word
Bits
Summary of Contents for CP1L CPU UNIT - 03-2009
Page 1: ...Cat No W462 E1 06 CP1L CPU Unit SYSMAC CP Series CP1L L_0D_ CP1L M_0D_ OPERATION MANUAL...
Page 2: ......
Page 4: ...iv...
Page 10: ...x...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 70: ...36 Function Blocks Section 1 5...
Page 584: ...550 Trouble Shooting Section 8 7...
Page 627: ...593 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 630: ...596 Sample Application Section 9 12...
Page 654: ...620 Troubleshooting Unit Errors Section 11 4...
Page 662: ...628 Replacing User serviceable Parts Section 12 2...
Page 668: ...634 Standard Models Appendix A...
Page 698: ...664 Auxiliary Area Allocations by Function Appendix C...
Page 746: ...712 Auxiliary Area Allocations by Address Appendix D...
Page 773: ...739 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 774: ...740 Connections to Serial Communications Option Boards Appendix F...
Page 806: ...772 Index...
Page 808: ...774 Revision History...