![background image](http://html1.mh-extra.com/html/omron/cp1l-cpu-unit-03-2009/cp1l-cpu-unit-03-2009_operation-manual_742084265.webp)
231
Pulse Outputs
Section 5-2
Specifying the Origin
Search Direction (CW or
CCW Direction)
Sets the direction to move when detecting the Origin Input Signal.
Typically, the origin search is performed so that the Origin Input Signal's rising
edge is detected when moving in the origin search direction.
Origin Search Speed
These are the motor speed settings used in the origin search.
Note
The origin search will not be performed in these cases:
Origin search high speed
≤
Origin search proximity speed
Origin search proximity speed
≤
Origin search initial speed
Origin Search/Return Initial Speed
Sets the motor's starting speed when the origin search is executed. Specify
the speed in the number of pulses per second (pps).
Origin Search High Speed
Sets the motor's target speed when the origin search is executed. Specify the
speed in the number of pulses per second (pps).
Origin Search Proximity Speed
Sets the motor's speed after the Origin Proximity Input Signal is detected.
Specify the speed in the number of pulses per second (pps).
Origin Search Acceleration Rate
Sets the motor's acceleration rate when the origin search is executed. Specify
the amount to increase the speed (Hz) per 4-ms interval.
Origin Search Deceleration Rate
Sets the motor's acceleration rate when the origin search function is deceler-
ating. Specify the amount to decrease the speed (Hz) per 4-ms interval.
Origin Compensation
After the origin has been determined, the origin compensation can be set to
compensate for a shift in the Proximity Sensor's ON position, motor replace-
ment, or other change.
2: Origin Proximity Input
Signal not used.
Note
When the limit input signal is received, the motor stops without deceleration.
Origin search
operation
Origin detection
method
1: Reversal mode 2
1
0
CCW
CCW
CCW
CW
CW
CW
Origin Input
Signal
Pulse output
Proximity speed for origin search
Start
Stop
CW limit input signal (See note.)
Start
Stop
Start
Limit stop (error code 0201)
Setting
Description
0
CW direction
1
CCW direction
Summary of Contents for CP1L CPU UNIT - 03-2009
Page 1: ...Cat No W462 E1 06 CP1L CPU Unit SYSMAC CP Series CP1L L_0D_ CP1L M_0D_ OPERATION MANUAL...
Page 2: ......
Page 4: ...iv...
Page 10: ...x...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 70: ...36 Function Blocks Section 1 5...
Page 584: ...550 Trouble Shooting Section 8 7...
Page 627: ...593 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 630: ...596 Sample Application Section 9 12...
Page 654: ...620 Troubleshooting Unit Errors Section 11 4...
Page 662: ...628 Replacing User serviceable Parts Section 12 2...
Page 668: ...634 Standard Models Appendix A...
Page 698: ...664 Auxiliary Area Allocations by Function Appendix C...
Page 746: ...712 Auxiliary Area Allocations by Address Appendix D...
Page 773: ...739 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 774: ...740 Connections to Serial Communications Option Boards Appendix F...
Page 806: ...772 Index...
Page 808: ...774 Revision History...