STEP 1:  QUICK OVERVIEW 

 

STEP 1.1: EK-TIM Indigo Xtreme:

 

Engineered Thermal Interface compatible with         

AMD FX,™ Phenom,™ and Athlon™

 

Indigo Xtreme™ is an Engineered Thermal Interface (ETI) 

that fits neatly between a CPU lid and heat sink or water 

block  to  keep  CPUs  cooler.  Unlike  greases,  metallic 

thermal  interface  pads  or  liquid  metal  alloys,  Indigo 

Xtreme is a self-contained and sealed structure, deploying 

a Phase Change Metallic Alloy (PCMA) which reflows and 

fills  surface  defects  on  the  CPU  lid  and  heat  sink.  The 

resultant interfacial layer is void-free and robust, with low 

thermal contact and bulk resistance. 

 

 

Important: Unlike most thermal interface products, the Indigo Xtreme form-factor is 

optimized for each application.  

 

Attempting to use Indigo Xtreme with CPUs or heat sinks other than those specified 

may result in degraded performance or interfacial failure (See: Supported Hardware). 

 

 

STEP 1.2: Compatibility List: 

 

Supported Hardware: 

Supported CPUs: 

All lidded AMD FX,™ 

 

Phenom™ and Athlon™ Processors 

 

 

Supported Waterblock/Heat Sink Types:  

In general, water blocks and heat sinks that contact entire surface of CPU lid are compatible with Indigo 

Xtreme. All EKWB CPU series water blocks water blocks are supported! 

 

Unsupported Heat Sink Types:  

Heat sinks that do not contact entire surface of CPU lid,  

or surfaces with channels between mounting base and  

heat pipes, are incompatible with Indigo Xtreme.  

 

 

 

Prior to the installation and reflow of Indigo Xtreme 

do not disable

 the Thermal Control 

feature that protects your CPU from overheating. 

 

STEP 2:  INSTALLATION PROCEDURE 

STEP 1.3: ETI Kit Contents:

 

The  Indigo  Xtreme  ETI  is  offered  as  part  of  an  Engineered  Thermal  Interface  Kit.  This  kit 

includes several cleanroom-grade surface cleaning products for (2) complete installations.  

 

The ETI kit includes:  

   Indigo Xtreme ETIs (2 installations) 

   Cleanroom-grade dry wiper cloths  

   Indigo Xtreme Clean™ (sample size) 

   Pair of powder-free nitrile gloves  

   Detailed Installation Guide 

 

 

Check  the  condition  of  the  ETI  kit  before  installation;  if  any  problem  is  found, 

contact Enerdyne Solutions for a replacement.  

 

 

 

This  FX  compatible  installation  guide  differs  from  other  Indigo  Xtreme 

models. Read  entire  instructions  before  beginning  installation.  Computer 

operating system and temperature monitoring utilities must be installed prior to 

use. Contact EKWB Support if you have any questions.  

 

 

STEP 2.1: Motherboard, CPU and Heat Sink/Block Removal:

 

Remove the motherboard (from the PC case) and all heat sink clips and support mechanisms from the 

motherboard.  Remove  the  CPU  from  the  motherboard  socket  and  place  on  a  non-abrasive,  lint-free 

surface for cleaning. 

 

STEP 2.2: Thermal Interface (grease) Compound Removal:   

Using the supplied dry wiper cloth, apply pressure to thoroughly remove any existing interface 

grease from the CPU lid and heat sink. Clean with fresh areas of the wiper cloth until no visible 

grease residue is detected on the wiper.  

  

 

If removing metal pad or liquid metal TIM residue, refer to manufacturer’s specific 

cleaning methods. 

 

STEP 2.3: Put on Gloves:  

Prior to the final degreasing step, the supplied powder-free nitrile gloves must be worn to prevent any 

finger oils or contaminants from contacting the CPU lid, heat sink and ETI surfaces and to prevent skin 

contact with Indigo Xtreme Clean™.  

  

 

Stray grease compound can be  mitigated as gloves are applied  immediately  following the 

Thermal Interface Compound Removal step. 

 

Installation manual for 

EK-TIM Indigo Extreme™

 

Summary of Contents for EK-TIM Indigo Extreme

Page 1: ...at do not contact entire surface of CPU lid or surfaces with channels between mounting base and heat pipes are incompatible with Indigo Xtreme Prior to the installation and reflow of Indigo Xtreme do not disable the Thermal Control feature that protects your CPU from overheating STEP 2 INSTALLATION PROCEDURE STEP 1 3 ETI Kit Contents The Indigo Xtreme ETI is offered as part of an Engineered Therma...

Page 2: ...e ETI STEP 2 7 Bottom Side Liner Removal Remove the Bottom side rectangular clear liner by slowly peeling the liner beginning from the corner with the white BOTTOM label Hold the ETI on the blue edges with both hands to prevent any wrinkling or warping Do not remove the Top liner at this step Do not touch the exposed adhesive area after removal of the clear liner Once the liner has been removed pr...

Page 3: ...nd full copper water blocks will require longer reflow times All FX CPUs All other AM3 CPUs 1 PC is off at room temperature motherboard is in a horizontal position and all pumps and fans are unplugged PC is off at room temperature motherboard is in a horizontal position and all pumps and fans are unplugged 2 Upon booting into BIOS displayed CPU temperature will steadily rise to a peak temperature ...

Page 4: ...quire a new ETI All interface material and adhesive residue must be removed and the CPU and heat sink re cleaned with the surface cleaning supplies including in the ETI kit only prior to the re installation of a new ETI REFERENCES The Material Safety Data Sheet MSDS for Indigo Xtreme Clean can be found at http www ekwaterblocks com shop EK IM MSDS_Indigo pdf Contact us for more information about t...