581
Web Browser Setup and Display
Section 9-10
9-10-7 FINS/TCP
FINS/TCP Connection Setup
The functions of the buttons are as follows.
Item
Contents
Default
No.
Shows the connection number. This is a network API
used when TCP is used for the FINS communica-
tions service. Up to 2 can be used at a time, and
they are identified by connection numbers 1 to 2.
The Ethernet Option Board can thus simultaneously
execute the FINS communications service by TCP
with up to 2 remote nodes.
---
IP Address
• When the Ethernet Option Board is used as a server:
If the option is selected to use IP addresses to pro-
tect, set the IP addresses as required at clients
from which connection is permitted. If not set for
those connections, the default setting can be used.
•
When the Ethernet Option Board is used as a client:
Set the IP address for the remote Ethernet Unit
(i.e., the server) that is to be connected by
FINS/TCP. It is required that an IP address be set
for the remote Ethernet Unit.
0.0.0.0
Auto-allocated
FINS node
If the client (normally a personal computer) applica-
tion supports FINS/TCP, and if FINS node addresses
are not fixed, the client will take 0 as its node
address. Then, when a FINS command arrives, the
number set here (from 251 to 252) will automatically
be allocated as the client’s FINS node address.
From 251 to
252, for
connection
No. 1 to 2
Button
Function
Transfer
Transfer the entered values from the personal computer to the
Ethernet Option Board. (The new settings are invalid until the
Ethernet Option Board has been reset.)
Cancel
Cancel the entered values.
Restart
Restart the Ethernet Option Board to enable the new settings
after transfer.
The Restart button is invalid to the PLC.
Summary of Contents for CP1L CPU UNIT - 03-2009
Page 1: ...Cat No W462 E1 06 CP1L CPU Unit SYSMAC CP Series CP1L L_0D_ CP1L M_0D_ OPERATION MANUAL...
Page 2: ......
Page 4: ...iv...
Page 10: ...x...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 70: ...36 Function Blocks Section 1 5...
Page 584: ...550 Trouble Shooting Section 8 7...
Page 627: ...593 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 630: ...596 Sample Application Section 9 12...
Page 654: ...620 Troubleshooting Unit Errors Section 11 4...
Page 662: ...628 Replacing User serviceable Parts Section 12 2...
Page 668: ...634 Standard Models Appendix A...
Page 698: ...664 Auxiliary Area Allocations by Function Appendix C...
Page 746: ...712 Auxiliary Area Allocations by Address Appendix D...
Page 773: ...739 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 774: ...740 Connections to Serial Communications Option Boards Appendix F...
Page 806: ...772 Index...
Page 808: ...774 Revision History...