49
Specifications
Section 2-2
Note
Can be used as Modbus-RTU easy master function.
Serial
port
Peripheral
USB port
Supported. (1-port USB connector, type B): Special for a Peripheral Device such as the CX-Pro-
grammer. (Set the network classification to USB in the Peripheral Device's PLC model setting.)
• Serial communications standard: USB 1.1
RS-232C
port,
RS-422A/485
port
Ports not provided as standard equipment. (M-type CPU Unit: 2 ports max.,
L-type CPU Unit: 1 port)
The following Option Boards can be mounted:
• CP1W-CIF01: One RS-232C port
• CP1W-CIF11/CIF12: One RS-422A/485 port
Applicable communications modes (same for all of the above ports): Host Link,
NT Link (1: N mode), No-protocol, Serial PLC Link Slave, Serial PLC Link Master,
Serial Gateway (conversion to CompoWay/F, conversion to Modbus-RTU),
peripheral bus (See note.)
Not Support
Number of tasks
288 (32 cycle execution tasks and 256 interrupt tasks)
Scheduled
interrupt
1 (interrupt task 2, fixed)
Input
interrupt tasks
6 (interrupt tasks 140 to 145, fixed)
4 (interrupt
tasks 140 to
143, fixed)
2 (interrupt
tasks 140 to
141, fixed)
(High-speed counter interrupts and interrupt tasks specified by external interrupts
can also be executed.)
Maximum subroutine
number
256
Maximum jump
number
256
Scheduled interrupts
1
Clock function
Supported.
Accuracy (monthly deviation):
4.5 min to
−
0.5 min (ambient temperature: 55
°
C),
−
2.0 min to +2.0 min (ambient temperature: 25
°
C),
−
2.5 min to +1.5 min (ambient temperature: 0
°
C)
Memory
Backup
Built-in flash
memory
User programs and parameters (such as the PLC Setup) are automatically saved to the flash
memory. It is also possible to save and read data memory initial data.
The data is automatically transferred to RAM when the power supply is turned ON. (Data memory
initial data, however, may or may not be transferred, depending on the selection in the PLC Setup.
Battery
backup
The HR Area, DM Area, and counter values (flags, PV) are backed up by a battery.
Battery model: CJ1W-BAT01 (Built into the CP1L CPU Unit.)
Maximum battery service life: 5 years
Guaranteed (ambient temperature: 55°C): 13,000 hours (approx. 1.5 years)
Effective value (ambient temperature: 25°C): 43,000 hours (approx. 5 years)
Memory Cassette
function
A CP1W-ME05M Memory Cassette (512K words, optional) can be mounted. It can be used to
back up the following data on the CPU Unit's RAM and to transfer the data at startup.
• Data saved on Memory Cassette: User programs, parameters (such as the PLC Setup), DM
Area, data memory initial data, comment memory (CX-Programmer conversion tables, com-
ments, program indices), and FB program memory.
• Writing to Memory Cassette: By operations from the CX-Programmer.
• Reading from Memory Cassette: At startup, or by operations from the CX-Programmer.
Type
M CPU Units
L CPU Units
Model
CP1L-M60DR-A
CP1L-M60DR-D
CP1L-M60DT-A
CP1L-M60DT-D
CP1L-M60DT1-D
CP1L-M40DR-A
CP1L-M40DR-D
CP1L-M40DT-A
CP1L-M40DT-D
CP1L-M40DT1-D
CP1L-M30DR-A
CP1L-M30DR-D
CP1L-M30DT-A
CP1L-M30DT-D
CP1L-M30DT1-D
CP1L-L20DR-A
CP1L-L20DR-D
CP1L-L20DT-A
CP1L-L20DT-D
CP1L-L20DT1-D
CP1L-L14DR-A
CP1L-L14DR-D
CP1L-L14DT-A
CP1L-L14DT-D
CP1L-L14DT1-D
CP1L-L10DR-A
CP1L-L10DR-D
CP1L-L10DT-A
CP1L-L10DT-D
CP1L-L10DT1-D
Summary of Contents for CP1L CPU UNIT - 03-2009
Page 1: ...Cat No W462 E1 06 CP1L CPU Unit SYSMAC CP Series CP1L L_0D_ CP1L M_0D_ OPERATION MANUAL...
Page 2: ......
Page 4: ...iv...
Page 10: ...x...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 70: ...36 Function Blocks Section 1 5...
Page 584: ...550 Trouble Shooting Section 8 7...
Page 627: ...593 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 630: ...596 Sample Application Section 9 12...
Page 654: ...620 Troubleshooting Unit Errors Section 11 4...
Page 662: ...628 Replacing User serviceable Parts Section 12 2...
Page 668: ...634 Standard Models Appendix A...
Page 698: ...664 Auxiliary Area Allocations by Function Appendix C...
Page 746: ...712 Auxiliary Area Allocations by Address Appendix D...
Page 773: ...739 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 774: ...740 Connections to Serial Communications Option Boards Appendix F...
Page 806: ...772 Index...
Page 808: ...774 Revision History...