MAINTENANCE AND SERVICING
7. Match slots on new bulb (B) with lugs (D) in optical unit
and insert bulb into unit.
8. Secure bulb with wire retainer (A).
9. Push wire into connector (C).
Figure 5.146: Flood Light Assembly
10. Position light into light receptacle, ensuring top is up
and secure with bezel (C) and screws (B).
Figure 5.147: Forward Flood Light
High-Intensity Discharge (HID) Auxiliary Lighting (Optional - MD #B5596)
Two optional HID lights provide additional lighting during
fi
eld operation. They operate only in cab-forward mode.
Adjusting High-Intensity Discharge (HID) Auxiliary Lights (if Installed)
If installed, HID auxiliary lights are best adjusted with the machine in the
fi
eld (or equivalent) to suit
Operator preference.
DANGER
To avoid bodily injury or death from unexpected startup of the machine, always stop the engine and remove
the key from the ignition before leaving the operator’s seat for any reason.