REFERENCE
Fault
Code
J1939
SPN
J1939
FMI
Lamp
Color
J1939 SPN
Description
Cummins Description
45
268
94
2
Amber
Fuel Delivery
Pressure
Fuel Pressure Sensor Circuit - Data Erratic,
Intermittent, or Incorrect
271
1347
4
Amber
Fuel Pump
Pressurizing
Assembly #1
High Fuel Pressure Solenoid Valve Circuit –
Voltage Below Normal, or Shorted to Low Source
272
1347
3
Amber
Fuel Pump
Pressurizing
Assembly #1
High Fuel Pressure Solenoid Valve Circuit –
Voltage Above Normal, or Shorted to High Source
281
1347
7
Amber
Fuel Pump
Pressurizing
Assembly #1
High Fuel Pressure Solenoid Valve #1 –
Mechanical System Not Responding Properly or
Out of Adjustment
284
1043
4
Amber
Internal Sensor
Voltage Supply
Engine Speed/Position Sensor (Crankshaft)
Supply Voltage Circuit - Voltage Below Normal, or
Shorted to Low Source
285
639
9
Amber
SAE J1939 Datalink SAE J1939 Multiplexing PGN Timeout Error -
Abnormal Update Rate
286
639
13
Amber
SAE J1939 Datalink SAE J1939 Multiplexing Con
fi
guration Error – Out
of Calibration
SAE J1939 Multiplexing Accelerator Pedal or
Lever Sensor System Error - Received Network
287
91
19
Red
Accelerator Pedal
Position
Data In Error
288
974
19
Red
Remote
Accelerator
SAE J1939 Multiplexing Remote Accelerator
Pedal or Lever Data Error - Received Network
Data In Error
292
441
14
Red
Auxiliary
Temperature 1
Auxiliary Temperature Sensor Input 1 - Special
Instructions
293
441
3
Amber
OEM Temperature
Auxiliary Temperature Sensor Input # 1 Circuit -
Voltage Above Normal, or Shorted to High Source
294
441
4
Amber
OEM Temperature
Auxiliary Temperature Sensor Input # 1 Circuit -
Voltage Below Normal, or Shorted to Low Source
295
108
2
Amber
Barometric
Pressure
Barometric Pressure Sensor Circuit - Data Erratic,
Intermittent, or Incorrect
296
1388
14
Red
Auxiliary Pressure
Auxiliary Pressure Sensor Input 1 - Special
Instructions
297
1388
3
Amber
Auxiliary Pressure
Auxiliary Pressure Sensor Input # 2 Circuit -
Voltage Above Normal, or Shorted to High Source
298
1388
4
Amber
Auxiliary Pressure
Auxiliary Pressure Sensor Input # 2 Circuit -
Voltage Below Normal, or Shorted to Low Source
Real Time Clock Power Interrupt - Data Erratic,
319
251
2
Maint
Real Time Clock
Power
Intermittent, or Incorrect
322
651
5
Amber
Injector Cylinder
#01
Injector Solenoid Cylinder #1 Circuit – Current
Below Normal, or Open Circuit
147649
472
Revision A
Summary of Contents for M155
Page 3: ...Declaration of Conformity Figure 1 Declaration of Conformity Page 1 of 2 147649 i Revision A ...
Page 4: ...Figure 2 Declaration of Conformity Page 2 of 2 147649 ii Revision A ...
Page 30: ...SAFETY Figure 1 21 Safety Signs Left Cab forward Side 147649 14 Revision A ...
Page 32: ...SAFETY Figure 1 23 Safety Signs Right Cab forward Side 147649 16 Revision A ...
Page 44: ......
Page 54: ......
Page 320: ......
Page 414: ...MAINTENANCE AND SERVICING Fuse Box Decal Figure 5 178 Fuse Decal 147649 398 Revision A ...
Page 468: ......
Page 509: ......