OPERATION
NOTE:
If the header cannot return to the preset height or angle within 30 seconds, the RETURN TO CUT feature will
deactivate to prevent the hydraulic oil from overheating. Push the RETURN TO CUT switch (A) to reactivate.
4.4.8
Auto Raise Height
The header can be automatically raised if programmed into the cab display module (CDM).
Refer to the following topics:
•
Programming the Auto Raise Height Feature, page 209
•
Using the Auto Raise Height Feature, page 210
Programming the Auto Raise Height Feature
Figure 4.100: Operator Console
A - Return to Cut
B - Program
C - Select
D - Right Arrow
E - Left Arrow
F - Header Up
G - Header Down
Program the AUTO RAISE HEIGHT feature as follows:
NOTE:
RETURN TO CUT switch (A) can be OFF or ON.
1. Turn ignition ON or run engine.
2. Press PROGRAM (B) and SELECT (C) on cab display module (CDM) to enter programming mode.
3. Press SELECT (C). WINDROWER SETUP? is displayed on upper line (B).
147649