REFERENCE
Fault
Code
J1939
SPN
J1939
FMI
Lamp
Color
J1939 SPN
Description
Cummins Description
45
2363
1073
4
Amber
Engine
Compression Brake
Output # 2
Engine Brake Actuator Circuit #2 – Voltage Below
Normal, or Shorted to Low Source
2365
1112
4
Amber
Engine Brake
Output # 3
Engine Brake Actuator Driver Output 3 Circuit -
Voltage Below Normal, or Shorted to Low Source
2367
1073
3
Amber
Engine
Compression Brake
Output # 2
Engine Brake Actuator Circuit #2 – Voltage Above
Normal, or Shorted to High Source
2368
1112
3
Amber
Engine Brake
Output # 3
Engine Brake Actuator Driver 3 Circuit - Voltage
Above Normal, or Shorted to High Source
2372
95
16
Amber
Engine Fuel
Filter Differential
Pressure
Fuel Filter Differential Pressure - Data Valid but
Above Normal Operational Range - Moderately
Severe Level
2373
1209
3
Amber
Exhaust Gas
Pressure
Exhaust Gas Pressure Sensor Circuit - Voltage
Above Normal, or Shorted to High Source
2374
1209
4
Amber
Exhaust Gas
Pressure
Exhaust Gas Pressure Sensor Circuit - Voltage
Below Normal, or Shorted to Low Source
2375
412
3
Amber
Exhaust Gas
Recirculation
Temperature
Exhaust Gas Recirculation Temperature Sensor
Circuit - Voltage Above Normal, or Shorted to
High Source
2376
412
4
Amber
Exhaust Gas
Recirculation
Temperature
Exhaust Gas Recirculation Temperature Sensor
Circuit - Voltage Below Normal, or Shorted to Low
Source
2377
647
3
Amber
Fan Clutch Output
Device Driver
Fan Control Circuit - Voltage Above Normal, or
Shorted to High Source
2425
730
4
Intake Air Heater #
2
Intake Air Heater 2 Circuit - Voltage Below Normal,
or Shorted to Low Source
2426
730
3
Intake Air Heater #
2
Intake Air Heater 2 Circuit - Voltage Above
Normal, or Shorted to High Source
2448
111
17
Amber/Blinkin
g
Coolant Level
Coolant Level - Data Valid But Below Normal
Operating Range - Least Severe Level
2555
729
3
Amber
Inlet Air Heater
Driver #1
Intake Air Heater #1 Circuit - Voltage Above
Normal, or Shorted to High Source
2556
729
4
Amber
Inlet Air Heater
Driver #1
Intake Air Heater #1 Circuit - Voltage Below
Normal, or Shorted to Low Source
2557
697
3
Amber
Auxiliary PWM
Driver #1
Auxiliary PWM Driver #1 - Voltage Above Normal,
or Shorted to High Source
2558
697
4
Amber
Auxiliary PWM
Driver #1
Auxiliary PWM Driver #1 - Voltage Below Normal,
or Shorted to Low Source
147649
479
Revision A
Summary of Contents for M155
Page 3: ...Declaration of Conformity Figure 1 Declaration of Conformity Page 1 of 2 147649 i Revision A ...
Page 4: ...Figure 2 Declaration of Conformity Page 2 of 2 147649 ii Revision A ...
Page 30: ...SAFETY Figure 1 21 Safety Signs Left Cab forward Side 147649 14 Revision A ...
Page 32: ...SAFETY Figure 1 23 Safety Signs Right Cab forward Side 147649 16 Revision A ...
Page 44: ......
Page 54: ......
Page 320: ......
Page 414: ...MAINTENANCE AND SERVICING Fuse Box Decal Figure 5 178 Fuse Decal 147649 398 Revision A ...
Page 468: ......
Page 509: ......