REFERENCE
Fault
Code
J1939
SPN
J1939
FMI
Lamp
Color
J1939 SPN
Description
Cummins Description
45
144
110
3
Amber
Engine Coolant
Temperature
Coolant Temperature Sensor Circuit – Voltage
Above Normal, or Shorted to High Source
145
110
4
Amber
Engine Coolant
Temperature
Coolant Temperature Sensor Circuit – Voltage
Below Normal, or Shorted to Low Source
146
110
16
Amber
Engine Coolant
Temperature
Coolant Temperature High - Data Valid but Above
Normal Operational Range - Moderately Severe
Level
147
91
1
Red
Accelerator Pedal
Position
Accelerator Pedal or Lever Position Sensor Circuit
– Abnormal Frequency, Pulse Width, or Period
148
91
0
Red
Accelerator Pedal
Position
Accelerator Pedal or Lever Position Sensor Circuit
– Abnormal Frequency, Pulse Width, or Period
151
110
0
Red
Engine Coolant
Temperature
Coolant Temperature High - Data Valid but Above
Normal Operational Range - Most Severe Level
153
105
3
Amber
Intake Manifold #1
Temp
Intake Manifold Air Temperature Sensor Circuit -
Voltage Above Normal, or Shorted to High
154
105
4
Amber
Intake Manifold #1
Temp
Intake Manifold Air Temperature Sensor Circuit -
Voltage Below Normal, or Shorted to Low Source
155
105
0
Red
Intake Manifold #1
Temp
Intake Manifold Air Temperature High – Data Valid
but Above Normal Operational Range - Most
Severe Level
187
3510
4
Amber
5 Volts DC Supply
Sensor Supply Voltage #2 Circuit – Voltage Below
Normal, or Shorted to Low Source
193
52019 9
3
Amber
Cruise Control
Cruise Control (Resistive) Signal Circuit - Voltage
Above Normal, or Shorted to High Source
194
52019 9
4
Amber
Cruise Control
Cruise Control (Resistive) Signal Circuit - Voltage
Below Normal, or Shorted to Low Source
195
111
3
Amber
Coolant Level
Coolant Level Sensor Circuit - Voltage Above
Normal, or Shorted to High Source
196
111
4
Amber
Coolant Level
Coolant Level Sensor Circuit - Voltage Below
Normal, or Shorted to Low Source
197
111
18
Amber
Coolant Level
Coolant Level - Data Valid but Below Normal
Operational Range - Moderately Severe Level
199
1661
4
Amber
Engine Automatic
Start Lamp
Engine Automatic Start Lamp Driver Circuit -
Voltage Above Normal, or Shorted to High Source
211
1484
31
None
J1939 Error
Additional Auxiliary Diagnostic Codes logged -
Condition Exists
212
175
3
Amber
Oil Temperature
Engine Oil Temperature Sensor 1 Circuit - Voltage
Above Normal, or Shorted to High Source
213
175
4
Amber
Oil Temperature
Engine Oil Temperature Sensor 1 Circuit - Voltage
Below Normal, or Shorted to Low Source
214
175
0
Red
Oil Temperature
Engine Oil Temperature - Data Valid but Above
Normal Operational Range - Most Severe Level
147649
470
Revision A
Summary of Contents for M155
Page 3: ...Declaration of Conformity Figure 1 Declaration of Conformity Page 1 of 2 147649 i Revision A ...
Page 4: ...Figure 2 Declaration of Conformity Page 2 of 2 147649 ii Revision A ...
Page 30: ...SAFETY Figure 1 21 Safety Signs Left Cab forward Side 147649 14 Revision A ...
Page 32: ...SAFETY Figure 1 23 Safety Signs Right Cab forward Side 147649 16 Revision A ...
Page 44: ......
Page 54: ......
Page 320: ......
Page 414: ...MAINTENANCE AND SERVICING Fuse Box Decal Figure 5 178 Fuse Decal 147649 398 Revision A ...
Page 468: ......
Page 509: ......