OPERATOR’S STATION
1. Turn ignition key to RUN, or start the engine.
2. Press PROGRAM (A) and SELECT (C) on cab display
module (CDM) to enter Programming Mode.
• WINDROWER SETUP? is displayed on the
upper line.
3. Press SELECT (C) until CALIBRATE SENSORS? is
displayed on the upper line.
• NO/YES is displayed on the lower line.
Figure 3.85: M155 CDM Programming Buttons
4. Press right (B) arrow to select Yes. Press SELECT (C).
• TO CALIBRATE SELECT is displayed in upper line.
5. Press left (A) or right (B) arrow until HEADER HEIGHT
is displayed on the lower line. Press SELECT (C).
• CALIBRATING HEIGHT is displayed on the
upper line.
• RAISE HEADER HOLD is displayed on the
lower line.
Figure 3.86: M155 Header Height Calibration