The Execution Unit does not connect directly to the system bus. It obtains instructions from a
queue maintained by the Bus Interface Unit. When an instruction requires access to memory or a
peripheral device, the Execution Unit requests the Bus Interface Unit to read and write data. Ad-
dresses manipulated by the Execution Unit are 16 bits wide. The Bus Interface Unit, however,
performs an address calculation that allows the Execution Unit to access the full megabyte of
memory space.
To execute an instruction, the Execution Unit must first fetch the object code byte from the in-
struction queue and then execute the instruction. If the queue is empty when the Execution Unit
is ready to fetch an instruction byte, the Execution Unit waits for the Bus Interface Unit to fetch
the instruction byte.
2.1.2
Bus Interface Unit
The 80C186 Modular Core and 80C188 Modular Core Bus Interface Units are functionally iden-
tical. They are implemented differently to match the structure and performance characteristics of
their respective system buses. The Bus Interface Unit executes all external bus cycles. This unit
consists of the segment registers, the Instruction Pointer, the instruction code queue and several
miscellaneous registers. The Bus Interface Unit transfers data to and from the Execution Unit on
the ALU data bus.
The Bus Interface Unit generates a 20-bit physical address in a dedicated adder. The adder shifts
a 16-bit segment value left 4 bits and then adds a 16-bit offset. This offset is derived from com-
binations of the pointer registers, the Instruction Pointer and immediate values (see Figure 2-2).
Any carry from this addition is ignored.
Figure 2-2. Physical Address Generation
Shift left 4 bits
2
1
3
4
0
0
2
2
0
0
0
15
19
+
= 1
19
2
3
6
2
0
Physical Address
To Memory
2
2
0
0
0
15
4
3
0
2
1
15
Segment Base
Offset
Logical
Address
A1500-0A
Summary of Contents for 80C186XL
Page 1: ...80C186XL 80C188XL Microprocessor User s Manual...
Page 2: ...80C186XL 80C188XL Microprocessor User s Manual 1995...
Page 18: ...1 Introduction...
Page 19: ......
Page 27: ......
Page 28: ...2 Overview of the 80C186 Family Architecture...
Page 29: ......
Page 79: ......
Page 80: ...3 Bus Interface Unit...
Page 81: ......
Page 127: ......
Page 128: ...4 Peripheral Control Block...
Page 129: ......
Page 137: ......
Page 138: ...5 ClockGenerationand Power Management...
Page 139: ......
Page 154: ...6 Chip Select Unit...
Page 155: ......
Page 178: ...7 Refresh Control Unit...
Page 179: ......
Page 193: ......
Page 194: ...8 Interrupt Control Unit...
Page 195: ......
Page 227: ......
Page 228: ...9 Timer Counter Unit...
Page 229: ......
Page 253: ......
Page 254: ...10 Direct Memory Access Unit...
Page 255: ......
Page 283: ......
Page 284: ...11 Math Coprocessing...
Page 285: ......
Page 302: ...12 ONCE Mode...
Page 303: ......
Page 306: ...A 80C186 Instruction Set Additions and Extensions...
Page 307: ......
Page 318: ...B Input Synchronization...
Page 319: ......
Page 322: ...C Instruction Set Descriptions...
Page 323: ......
Page 371: ......
Page 372: ...D Instruction Set Opcodes and Clock Cycles...
Page 373: ......
Page 396: ...Index...
Page 397: ......