Table 2. Firmware Checkpoints (continued)
Checkpoint
Description
Action/
Possible Failing FRU
E1F6
Determine boot device sequence
Go to “MAP 1542: I/O Problem Isolation” on
page 261.
E1F7
No boot image located
Go to “Boot Problems” on page 342.
E1F8
Partition (system firmware) is waiting for a
virtual terminal to be opened on HMC.
Open a virtual terminal for the partition on
the HMC.
If the partition hangs at this checkpoint after
a virtual terminal is opened on the HMC:
1. Replace the service processor/RIO
book, location: U1.18-P1-H2
2. Call service support.
E1FA
Building boot device list for SCSI adapters.
(The device ID and the device LUN being
scanned code are also displayed.)
1. If a location code is available, follow the
actions listed for error code 21A0 00xx.
2.
Go to “MAP 1542: I/O Problem
Isolation” on page 261.
E1FB
Scan SCSI bus for attached devices
1. If a location code is available, follow the
Repair actions listed for error code
21A0 00XX.
2. If no location code is available, go to
“MAP 1542: I/O Problem Isolation” on
page 261.
E1FC
Building boot device list for SSA adapters.
The location code of the SSA adapter being
scanned is also displayed.
Go to “MAP 1542: I/O Problem Isolation” on
page 261.
E1FD
The operator panel alternates between the
code E1FD and another Exxx code, where
Exxx is the point at which the error
occurred.
1. If a location code is available, follow the
actions listed for error code 21A0 00xx.
2. If no location code is available, go to
“MAP 1542: I/O Problem Isolation” on
page 261.
E1FE
Building boot device list for fibre-channel
adapters. (The WWPN of the SAN adapter
being scanned is also displayed.)
Go to “MAP 1542: I/O Problem Isolation” on
page 261.
E1FF
Building boot device list for fibre-channel
adapters. (The WWPN of the SAN adapter
being scanned is also displayed.)
Go to “MAP 1542: I/O Problem Isolation” on
page 261.
E20F
System firmware has exited to open
firmware prompt.
1. Replace the primary I/O book,
Location: U1.18-P1-H2.
2. Call service support.
E440
Validate NVRAM, initialize partitions as
needed
1. Check for system firmware updates.
2. Replace the primary I/O book,
Location: U1.18-P1-H2.
3. Call service support.
E441
Generate /options node NVRAM
configuration variable properties
1. Check for system firmware updates.
2. Replace the primary I/O book,
Location: U1.18-P1-H2.
3. Call service support.
Chapter 4. Checkpoints
323
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......