MAP 154B: Insufficient Hardware Resources Problem Isolation
Step 154B-1
Record the error code, location code(s), and word 13 that sent you to this MAP.
Step 154B-2
Turn off the power.
Examine the amber logic-power LEDs of all installed processor subsystem DCAs.
Step 154B-3
Are all amber logic-power LEDs of all installed processor subsystem DCAs off?
No
Call for support.
Yes
Go to “Step 154B-4”.
Step 154B-4
Attention:
Before replacing any parts, examine the processor subsystem drawer to ensure that:
v
At least one MCM (processor) module is installed.
v
At least one memory card is installed.
v
At least one L3 cache module is installed.
v
The primary I/O book is installed.
Refer to the error code recorded in “Step 154B-1”. When using the listings below, note the error code
condition before you replace parts that are called out. Replace the following FRUs, if present, one at a
time:
Attention:
Some of the parts in the following list are modules that have a limit of three plug cycles.
Before replacing any of the modules in the following list, call for support.
v
First location code item recorded, if any, in “Step 154B-1”.
v
Second location code item recorded, if any, in “Step 154B-1”.
v
Third location code item recorded, if any, in “Step 154B-1”.
Note:
Replace the following FRUs only if they are associated with the word 13 that you recorded earlier.
If the value of word 13, recorded in “Step 154B-1”, is 4110 0000 or 4060 0000, replace the following:
v
Primary I/O book at U1.18-P1-H2 if not recorded in “Step 154B-1”.
If the value of word 13, recorded in “Step 154B-1”, is 403F 0000 or 40FF 0000, replace the following:
v
Memory book 0 at U1.18-P1-M2 if not recorded in “Step 154B-1”.
v
Memory book 1 at U1.18-P1-M3 if not recorded in “Step 154B-1”
v
Memory book 2 at U1.18-P1-M7 if not recorded in “Step 154B-1”
v
Memory book 3 at U1.18-P1-M6 if not recorded in “Step 154B-1”.
If the value of word 13, recorded in “Step 154B-1”, is 402F 0000, replace the following:
v
MCM module 0 at U1.18-P1-C1 if not recorded in “Step 154B-1”.
v
MCM module 2 at U1.18-P1-C4 if not recorded in“Step 154B-1”.
v
MCM module 1 at U1.18-P1-C3 if not recorded in “Step 154B-1”.
v
MCM module 3 at U1.18-P1-C2 if not recorded in “Step 154B-1”.
Chapter 3. Maintenance Analysis Procedures
305
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......