Error Code Description
Action/
Possible Failing FRU
20D0 0999 Operating system terminated with error string
Call service support.
A hypervisor dump may be available; see
“Hypervisor Dump Retrieval Procedure” on
page 696.
20D0 9001 Subsystem information not found in VPD
1. If the location code starts with U1.17 or
U1.18, the problem is in the system VPD
module on the media subsystem operator
panel. Replace the operator panel; do not
swap the old VPD module onto the new
operator panel. Call service support for
instructions on programming the VPD
information into the new VPD module.
2. If the location code indicates an I/O
subsystem, call service support.
20D0 9002 Subsystem machine type and model
information not found in VPD
1. If the location code starts with U1.17 or
U1.18, the problem is in the system VPD
module on the media subsystem operator
panel. Replace the operator panel; do not
swap the old VPD module onto the new
operator panel. Call service support for
instructions on programming the VPD
information into the new VPD module.
2. If the location code indicates an I/O
subsystem, call service support.
20D0 9003 Subsystem serial number information not
found in VPD
1. If the location code starts with U1.17 or
U1.18, the problem is in the system VPD
module on the media subsystem operator
panel. Replace the operator panel; do not
swap the old VPD module onto the new
operator panel. Call service support for
instructions on programming the VPD
information into the new VPD module.
2. If the location code indicates an I/O
subsystem, call service support.
20D0 9004 Subsystem machine type and model field is
empty in VPD
1. If the location code starts with U1.17 or
U1.18, the problem is in the system VPD
module on the media subsystem operator
panel. Replace the operator panel; do not
swap the old VPD module onto the new
operator panel. Call service support for
instructions on programming the VPD
information into the new VPD module.
2. If the location code indicates an I/O
subsystem, call service support.
418
Eserver
pSeries 670 Service Guide
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......