Step 1521-4
Independent faults are indicated on both sides of the BPA. Each side must be isolated separately. Call for
support.
This ends the procedure.
Step 1521-5
Check the External (Room) EPO Connection if used.
If a room emergency power off (EPO) circuit is used, the external room EPO circuit is connected to the
J02 connector on the lower edge of the UEPO Switch.
Is a cable connected into the connector J02 on the UEPO Switch?
NO
Go to “Step 1521-6”.
YES
Go to “Step 1521-7”.
Step 1521-6
Is the internal toggle switch on the EPO panel card set to the ’RM EPO BYPASS’ position?
NO
Set the internal toggle switch to the ’RM EPO BYPASS’ position, and go to
″
MAP 0410: Repair
Checkout
″
in the
RS/6000 and
Eserver
pSeries Diagnostic Information for Multiple Bus Systems
.
YES
Exchange the UEPO card assembly. Follow all the steps in the removal and replacement
procedure for the “Unit Emergency Power Off (UEPO) Card Assembly” on page 788. Go to “Step
1521-8” on page 150.
Step 1521-7
Note:
Read the Danger and Caution notices under “Safety Notices” on page xi before continuing with this
procedure.
Disconnect the cable from UEPO connector J02, and set the toggle switch to the ’RM EPO BYPASS’
position.
Does the UEPO CMPLT LED on at least one BPC become lit?
NO
Exchange the UEPO card assembly. Follow all the steps in the removal and replacement
procedure for the “Unit Emergency Power Off (UEPO) Card Assembly” on page 788. Go to “Step
1521-8” on page 150.
YES
Notify the customer that the room EPO circuit is defective at this connection and requires service.
This ends the procedure.
Chapter 3. Maintenance Analysis Procedures
149
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......