Error Code Description
Action/
Possible Failing FRU
4503 307C This error code indicates that the memory
repeat gard function has deconfigured or
partially deconfigured a memory book.
Do the following:
1. Go to the memory
configuration/deconfiguration menu, which is
under the system information menu in the
service processor menus.
Look at the status of the books. If any of
the books have a status of
″
manually
deconfigured
″
, reconfigure the books and
boot the system in a full system partition to
the SMS menus. Shut down the system and
look again at the status of the books.
If all of the books are still configured in the
memory configuration/deconfiguration menu,
the problem has been resolved.
If any of the books have a status of
″
deconfigured by the system
″
, either before
or after the boot to the SMS menus, go to
step 2.
2. Replace the memory book specified by the
location code.
4503 307D This error code indicates that the memory
repeat gard function has deconfigured or
partially deconfigured a memory book.
Do the following:
1. Go to the memory
configuration/deconfiguration menu, which is
under the system information menu in the
service processor menus.
Look at the status of the books. If any of
the books have a status of
″
manually
deconfigured
″
, reconfigure the books and
boot the system in a full system partition to
the SMS menus. Shut down the system and
look again at the status of the books.
If all of the books are still configured in the
memory configuration/deconfiguration menu,
the problem has been resolved.
If any of the books have a status of
″
deconfigured by the system
″
, either before
or after the boot to the SMS menus, go to
step 2.
2. Replace the memory book specified by the
location code.
Chapter 5. Error Code to FRU Index
615
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......