Error Code Description
Action/
Possible Failing FRU
4067 0EA0 Bus tests detected fault in MOPS service
processor code
1. Access the service processor error log. Find
the error log entry for the 406x 0EA0 error.
Look for a hardware error of the form 450x
yyyy, 460x yyyy, or 4B2x yyyy with a
timestamp within a few minutes of the 406x
0EA0 error. Follow the actions for this
hardware error.
2. If there is no hardware error in the service
processor error log with a timestamp that is
close to the 406x 0EA0 error, or following
the actions for the hardware error does not
resolve the problem, check for platform
firmware updates. If an update is available,
apply it.
3. If a platform firmware update is not
available, or the update does not correct the
problem, call service support.
4067 0EA1 Bus tests detected fault in processor subsystem
code on main processor
1. Check for operating system update.
2. Call service support.
4067 0EA2 Bus tests detected fault in PRD code on service
processor
1. Check for system firmware updates.
2. Call service support.
4067 0EA4 Bus tests detected fault in service processor
code
1. Check for system firmware updates.
2. Call service support.
4067 0EA5 PRD detected a problem in the FNM code
1. Check for system firmware updates.
2. Call service support.
4067 0EAA PRD: FNM is handling this error
1. Check for system firmware updates.
2. Call service support.
4067 0EAF Bus tests detected unknown service processor
code and system type
1. Check for system firmware updates.
2. Call service support.
4067 0EB0 Bus tests detected JTAG problem
Go to “MAP 1540: Problem Isolation
Procedures” on page 253.
4067 0EB1 Attention line 0 stuck fault
Go to “MAP 1540: Problem Isolation
Procedures” on page 253.
4067 0EB2 Attention line 1 stuck fault
Go to “MAP 1540: Problem Isolation
Procedures” on page 253.
4067 0EB3 Attention line 2 stuck fault
Go to “MAP 1540: Problem Isolation
Procedures” on page 253.
4067 0EB4 Attention line 3 stuck fault
Go to “MAP 1540: Problem Isolation
Procedures” on page 253.
4067 0EB5 Attention line 4 stuck fault
Go to “MAP 1540: Problem Isolation
Procedures” on page 253.
4067 0EB6 Attention line 5 stuck fault
Go to “MAP 1540: Problem Isolation
Procedures” on page 253.
4067 0EB7 Attention line 6 stuck fault
Go to “MAP 1540: Problem Isolation
Procedures” on page 253.
4067 0EB8 Attention line 7 stuck fault
Go to “MAP 1540: Problem Isolation
Procedures” on page 253.
Chapter 5. Error Code to FRU Index
495
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......