Error Code Description
Action/
Possible Failing FRU
1025 xx25 Fourth I/O subsystem in second rack (I/O
subsystem 8), DCA-2, cable fault
If there is no DCA in U1.18-P1-V8, second rack
(I/O go to “MAP 1520: Power” on page 144
subsystem 8), DCA-2, with these pairs of
location codes:
1. U2.19-V2/Q1 and U1.35-P2-X2/Q10
2. U2.19-V2/Q2 and U1.35-P1-X2/Q10
If there is a 6th DCA in U1.18-P1-V8, go to
“MAP 1520: Power” on page 144 with these
pairs of location codes:
1. U2.19-V2/Q1 and U1.35-P2-X1/Q10
2. U2.19-V2/Q2 and U1.35-P1-X1/Q10
1025 xx27 Problem with fan 2 and fan 4 in fourth I/O
subsystem in second rack (I/O subsystem 8)
1. DCA-2
Location U2.19–V2
2. Fan 2,
Location U2.19–F2
3. Fan 4,
Location U2.19–F4
1025 xx31 Fourth I/O subsystem in second rack (I/O
subsystem 8) I/O subsystem backplane 1 fault
U2.19-P1
1025 xx33 Seeprom fault on I/O subsystem backplane 1 in
fourth I/O subsystem in second rack (I/O
subsystem 8)
U2.19-P1
1025 xx41 Fourth I/O subsystem in second rack (I/O
subsystem 8) I/O subsystem backplane 2 fault
U2.19-P2
1025 xx43 Seeprom fault on I/O subsystem backplane 2 in
fourth I/O subsystem in second rack (I/O
subsystem 8)
U2.19-P2
1025 xx51 Fourth I/O subsystem in second rack (I/O
subsystem 8) DASD backplane 1 fault
U2.19-P3
1025 xx53 Seeprom fault on DASD backplane 1 in fourth
I/O subsystem in second rack (I/O subsystem 8)
U2.19-P3
1025 xx61 Fourth I/O subsystem in second rack (I/O
subsystem 8), DASD backplane 2 fault
U2.19-P4
1025 xx63 Seeprom fault on DASD backplane 2 in fourth
I/O subsystem in second rack (I/O subsystem 8)
U2.19-P4
1025 xx71 Fourth I/O subsystem in second rack (I/O
subsystem 8), DASD backplane 3 fault
U2.19-P5
1025 xx73 Seeprom fault on DASD backplane 3 in fourth
I/O subsystem in second rack (I/O subsystem 8)
U2.19-P5
1025 xx81 Fourth I/O subsystem in second rack (I/O
subsystem 8) DASD backplane 4 fault
U2.19-P6
1025 xx83 Seeprom fault on DASD backplane 4 in fourth
I/O subsystem in second rack (I/O subsystem 8)
U2.19-P6
1RRU 1C06
Go to “MAP 1527: An Airflow Loss Has Been
Detected” on page 160.
SPCNtoA
Go to “MAP 1529: There Is A Bulk Power
Assembly (BPA) Communication Failure” on
page 163.
Chapter 5. Error Code to FRU Index
411
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......