Error Code Description
Action/
Possible Failing FRU
101C 5Ax6 A DCA FRU whose firmware is too down-level to
function with the power subsystem has been
installed in the CEC. For the DCA to function,
the power subsystem controller must download
code to it. (The x indicates which DCA has the
down-level firmware.)
If the system is powered up:
1. Wait approximately 30 minutes, then press
the green start-of-service button followed by
the white end-of-service button.
2.
Look at the service action event log in
Service Focal Point. Verify that the 101C
5Ax6 error code did not reoccur; if it did not,
the update was successful. If the 101C 5Ax6
error code reoccurs, call service support.
If the system is powered down:
a. Wait approximately 30 minutes.
b. Look at the service action event log in
Service Focal Point. Verify that the 101C
5Ax6 error code did not reoccur after 30
minutes. If it did not, the update was
successful. If the 101C 5Ax6 error code
reoccurs, call service support.
101C 6014 Overcurrent or overvoltage problem with 2.5V in
processor subsystem
Go to “MAP 1520: Power” on page 144.
101C 6114 Overcurrent or overvoltage problem with 1.8V in
processor subsystem
Go to “MAP 1520: Power” on page 144.
101C 6124 Overcurrent or overvoltage problem with 1.5V in
processor subsystem
Go to “MAP 1520: Power” on page 144.
101C 6134 Overcurrent or overvoltage problem with 1.5V in
processor subsystem
Go to “MAP 1520: Power” on page 144.
101C 6144 Overcurrent or overvoltage problem with 3.3V in
processor subsystem (oscillator)
Go to “MAP 1520: Power” on page 144.
101C 6514 Overcurrent or overvoltage problem with 5.0V in
processor subsystem (autostart, standby)
Go to “MAP 1520: Power” on page 144.
101C 6814 Overcurrent or overvoltage problem with 2.5V in
processor subsystem
Go to “MAP 1520: Power” on page 144.
101C 6914 Overcurrent or overvoltage problem with 1.8V in
processor subsystem
Go to “MAP 1520: Power” on page 144.
101C 6924 Overcurrent or overvoltage problem with 1.5V in
processor subsystem
Go to “MAP 1520: Power” on page 144.
101C 6934 Overcurrent or overvoltage problem with 1.5V in
processor subsystem
Go to “MAP 1520: Power” on page 144.
101C 6944 Overcurrent or overvoltage problem with 3.3V in
processor subsystem (oscillator)
Go to “MAP 1520: Power” on page 144.
101C 6D14 Overcurrent or overvoltage problem with 5.0V in
processor subsystem (autostart, standby)
Go to “MAP 1520: Power” on page 144.
101C 7E06 No MCMs detected OR the actual number of
MCMs does not match the expected number of
MCMs
1. Verify that the processor MCMs are plugged
in a valid configuration.
2. Verify that the processor MCMs are seated
properly.
3. Verify the processor VPD cards in the
primary I/O book are of the proper number
and are positioned and seated correctly.
4. Call service support.
386
Eserver
pSeries 670 Service Guide
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......