Error Code Description
Action/
Possible Failing FRU
4069 0007 Memory tests detected fault in L3 VPD card
1. L3 VPD card
Location: U1.18-P1-H2.1
(Order the L3 cache module FRU to obtain
a new L3 VPD card. Return the L3 cache
module that was included in the FRU kit,
and the failing L3 VPD card as
″
new
defective
″
.)
2. Primary I/O book
Location: U1.18-P1-H2
4069 000A Memory tests detected fault in primary I/O book
1 (slot 0)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253.
4069 000B Memory tests detected fault in secondary I/O
book (slot 1)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253.
4069 000C Memory tests detected fault in I/O book 3 (slot
2)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253.
4069 000D Memory tests detected fault in I/O book 4 (slot
3)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253.
4069 000E CUoD capacity card
1. Replace the CUoD capacity card
Location: U1.18-P1-H2.2
2. Ask the customer to reenter the CUoD
activation keys.
4069 0010 Memory tests detected fault in Memory book
(slot 0)
Memory book (slot 0)
Location: U1.18-P1-M2
4069 0011 Memory tests detected fault in Memory book
(slot 1)
Memory book (slot 1)
Location: U1.18-P1-M3
4069 0012 Memory tests detected fault in Memory book
(slot 2)
Memory book (slot 2)
Location: U1.18-P1-M7
4069 0013 Memory tests detected fault in Memory book
(slot 3)
Memory book (slot 3)
Location: U1.18-P1-M6
4069 0014 Memory tests detected fault in Memory book
(slot 4)
Memory book (slot 4)
Location: U1.18-P1-M4
4069 0015 Memory tests detected fault in Memory book
(slot 5)
Memory book (slot 5)
Location: U1.18-P1-M8
4069 0016 Memory tests detected fault in Memory book
(slot 6)
Memory book (slot 6)
Location: U1.18-P1-M5
4069 0017 Memory tests detected fault in Memory book
(slot 7)
Memory book (slot 7)
Location: U1.18-P1-M1
4069 00B0 Memory tests detected possible problem with
bus controller or CSP code
1. Check for system firmware updates.
2. Primary I/O book,
Location: U1.18-P1-H2
3. Call service support.
4069 00B1 Memory tests detected possible problem with
bus controller
1. Check for system firmware updates.
2. Primary I/O book,
Location: U1.18-P1-H2
3. Call service support.
Chapter 5. Error Code to FRU Index
511
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......