Error Code Description
Action/
Possible Failing FRU
1022 xx15 Second I/O subsystem in second rack (I/O
subsystem 6), DCA-1, cable fault
Go to “MAP 1520: Power” on page 144 with
these pairs of location codes:
1. U2.5-V1/Q1 and U1.35-P2-X2/Q3
2. U2.5-V1/Q2 and U1.35-P1-X2/Q3
1022 xx17 Problem with fan 1 and fan 3 in second I/O
subsystem in second rack (I/O subsystem 6)
1. DCA-1
Location U2.5–V1
2. Fan 1,
Location U2.5–F1
3. Fan 3,
Location U2.5–F3
1022 xx21 Second I/O subsystem in second rack (I/O
subsystem 6), DCA-2
U2.5-V2
1022 xx23 Seeprom fault on DCA-2 in second I/O
subsystem in secondary rack (I/O subsystem 6)
U2.5-V2
1022 xx25 Second I/O subsystem in second rack (I/O
subsystem 6), DCA-2, cable fault
Go to “MAP 1520: Power” on page 144 with
these pairs of location codes:
1. U2.5-V2/Q1 and U1.35-P2-X2/Q4
2. U2.5-V2/Q2 and U1.35-P1-X2/Q4
1022 xx27 Problem with fan 2 and fan 4 in second I/O
subsystem in second rack (I/O subsystem 6)
1. DCA-2
Location U2.5–V2
2. Fan 2,
Location U2.5–F2
3. Fan 4,
Location U2.5–F4
1022 xx31 Second I/O subsystem in secondary rack (I/O
subsystem 6) I/O subsystem backplane 1 fault
U2.5-P1
1022 xx33 Seeprom fault on I/O subsystem backplane 1 in
second I/O subsystem in secondary rack (I/O
subsystem 6)
Broken 12C Bus
U2.5-P1
1022 xx41 Second I/O subsystem in secondary rack (I/O
subsystem 6) I/O subsystem backplane 2 fault
U2.5-P2
1022 xx43 Seeprom fault on I/O subsystem backplane 2 in
second I/O subsystem in secondary rack (I/O
subsystem 6)
U2.5-P2
1022 xx51 Second I/O subsystem in secondary rack (I/O
subsystem 6) DASD backplane 1 fault
U2.5-P3
1022 xx53 Seeprom fault on DASD backplane 1 in second
I/O subsystem in secondary rack (I/O subsystem
6)
U2.5-P3
1022 xx61 Second I/O subsystem in secondary rack (I/O
subsystem 6), DASD backplane 2 fault
U2.5-P4
1022 xx63 Seeprom fault on DASD backplane 2 in second
I/O subsystem in secondary rack (I/O subsystem
6)
U2.5-P4
1022 xx71 Second I/O subsystem in secondary rack (I/O
subsystem 6), DASD backplane 3 fault
U2.5-P5
Chapter 5. Error Code to FRU Index
399
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......