Error Code Description
Action/
Possible Failing FRU
2B20 0011 Processor is manually disabled.
Use the service processor menus to re-enable
the processor and reboot the system.
2B20 0012 This is an informational code that is generated
when the
cpu_deallocate
command is used
to take a processor off-line.
There is no action required.
To bring the processor back on-line, or back
into the system or partition configuration,
reboot the operating system.
2B20 0022 Processor is deconfigured by the system.
The processor has previously failed BIST or
POST. Replace the processor MCM indicated
by the location code associated with the error
code in the error log.
2B20 0031 Processor is failing POST
Replace the processor MCM indicated by the
location code associated with the error code
in the error log.
2B20 0042 Unknown processor card
Remove the unknown/unsupported processor
MCM.
2B20 8880 Unrecoverable processor subsystem error
If Linux is the only operating system on the
failing system, call service support.
If AIX is available, and the system is powered
off, replace the FRU indicated in the service
processor error log entry. If AIX is available
and the system has been rebooted, run online
AIX diagnostics and look for an AIX error log
entry in which the description says cache or
cache controller error. Replace the FRUs
listed in this entry.
2B20 8881 Software error
Call service support.
2B20 8882 Software error
Call service support.
2B20 8883 Software error
Call service support.
2B20 8884 Unrecoverable processor subsystem error
If Linux is the only operating system on the
failing system, call service support.
If AIX is available, and the system is powered
off, replace the FRU indicated in the service
processor error log entry. If AIX is available
and the system has been rebooted, run online
AIX diagnostics and look for an AIX error log
entry in which the description says cache or
cache controller error. Replace the FRUs
listed in this entry.
2B20 8885 Unrecoverable internal hardware error
If Linux is the only operating system on the
failing system, call service support.
If Aix is available, run online AIX
diagnostics.Look for an AIX error log entry in
which the description says I/O bus time out,
access, or other error, or I/O bridge/device
internal error. Replace the FRUs listed in this
entry.
2B20 8888 Operating system termination request
received
Informational message.
438
Eserver
pSeries 670 Service Guide
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......