Error Code Description
Action/
Possible Failing FRU
406A 0007 Self tests detected fault in L3 VPD card
1. L3 VPD card
Location: U1.18-P1-H2.1
(Order the L3 cache module FRU to obtain
a new L3 VPD card. Return the L3 cache
module that was included in the FRU kit,
and the failing L3 VPD card as
″
new
defective
″
.)
2. Primary I/O book
Location: U1.18-P1-H2
406A 000A Self tests detected fault in primary I/O book 1
(slot 0)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253.
406A 000B Self tests detected fault in secondary I/O book
(slot 1)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253.
406A 000C Self tests detected fault in I/O book 3 (slot 2)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253.
406A 000D Self tests detected fault in I/O book 4 (slot 3)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253.
406A 000E CUoD capacity card
1. Replace the CUoD capacity card
Location: U1.18-P1-H2.2
2. Ask the customer to reenter the CUoD
activation keys.
406A 0010 Self tests detected fault in Memory book (slot 0) Memory book (slot 0)
Location: U1.18-P1-M2
406A 0011 Self tests detected fault in Memory book (slot 1) Memory book (slot 1)
Location: U1.18-P1-M3
406A 0012 Self tests detected fault in Memory book (slot 2) Memory book (slot 2)
Location: U1.18-P1-M7
406A 0013 Self tests detected fault in Memory book (slot 3) Memory book (slot 3)
Location: U1.18-P1-M6
406A 0014 Self tests detected fault in Memory book (slot 4) Memory book (slot 4)
Location: U1.18-P1-M4
406A 0015 Self tests detected fault in Memory book (slot 5) Memory book (slot 5)
Location: U1.18-P1-M8
406A 0016 Self tests detected fault in Memory book (slot 6) Memory book (slot 6)
Location: U1.18-P1-M5
406A 0017 Self tests detected fault in Memory book (slot 7) Memory book (slot 7)
Location: U1.18-P1-M1
406A 00B0 Self tests detected possible problem with bus
controller or CSP code
1. Check for system firmware updates.
2. Primary I/O book,
Location: U1.18-P1-H2
3. Call service support.
406A 00B1 Self tests detected possible problem with bus
controller
1. Check for system firmware updates.
2. Primary I/O book,
Location: U1.18-P1-H2
3. Call service support.
Chapter 5. Error Code to FRU Index
525
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......