Error Code Description
Action/
Possible Failing FRU
4505 25D9 Memory subsystem and display alter tests
detected fault in L3 VPD card used with 1.1
GHz MCM and 1.3 GHz MCM
Go to “MAP 1548: Memory and Processor
Problem Isolation” on page 290.
4505 25E7 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
Go to “MAP 1548: Memory and Processor
Problem Isolation” on page 290.
4505 25E8 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
Go to “MAP 1548: Memory and Processor
Problem Isolation” on page 290.
4505 25F1 Memory subsystem and display alter tests
detected fault in L3 VPD card used with 1.3
GHz MCM
Go to “MAP 1548: Memory and Processor
Problem Isolation” on page 290.
4505 25F9 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
Go to “MAP 1548: Memory and Processor
Problem Isolation” on page 290.
4505 269A Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
Go to “MAP 1548: Memory and Processor
Problem Isolation” on page 290.
4505 28B0 Memory subsystem and display alter tests
detected fault in I/O subsystem PCI backplane
I/O subsystem PCI backplane at location
specified in error code
4505 28B1 Memory subsystem and display alter tests
detected fault in I/O subsystem DASD
backplane
I/O subsystem DASD backplane at location
specified in error code
4505 302A Memory subsystem and display alter tests
detected fault in 8 GB memory book (inner)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253 to isolate the failing
component.
4505 302B Memory subsystem and display alter tests
detected fault in 8 GB memory book (outer)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253 to isolate the failing
component.
4505 302C Memory subsystem and display alter tests
detected fault in 32 GB memory book (inner)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253 to isolate the failing
component.
4505 302D Memory subsystem and display alter tests
detected fault in 32 GB memory book (outer)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253 to isolate the failing
component.
4505 305A Memory subsystem and processor subsystem
tests detected fault in 8 GB memory book
(inner)
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
4505 305B Memory subsystem and processor subsystem
tests detected fault in 8 GB memory book
(outer)
Go to “MAP 1545: Outer L3 Module Problem
Isolation” on page 284.
4505 305C Memory subsystem and display alter tests
detected fault in 4 GB inner memory book
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
4505 305D Memory subsystem and display alter tests
detected fault in 4 GB outer memory book
Go to “MAP 1545: Outer L3 Module Problem
Isolation” on page 284.
4505 305E Memory subsystem and display alter tests
detected fault in 16 GB inner memory book
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
4505 305F Memory subsystem and display alter tests
detected fault in 16 GB outer memory book
Go to “MAP 1545: Outer L3 Module Problem
Isolation” on page 284.
4505 307A Memory subsystem and processor subsystem
tests detected fault in 4 GB inner memory book
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
4505 307B Memory subsystem and processor subsystem
tests detected fault in 8 GB inner memory book
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
Chapter 5. Error Code to FRU Index
625
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......