Error Code Description
Action/
Possible Failing FRU
1016 1B17 Problem with fan 1 in third I/O subsystem in
primary rack
1. DCA-1
Location: U1.1-V1
2. Fan 1
Location: U1.1-F1
1016 1B27 Problem with fan 2 in third I/O subsystem in
primary rack
1. DCA-2
Location: U1.1-V2
2. Fan 2
Location: U1.1-F2
1016 1C06 Loss of airflow in third I/O subsystem,
location: U1.1
Go to “MAP 1527: An Airflow Loss Has Been
Detected” on page 160.
1016 6014 Overcurrent or overvoltage problem with 3.3V in
third I/O subsystem
Go to “MAP 1520: Power” on page 144.
1016 6024 Overcurrent or overvoltage problem with 5.0V in
third I/O subsystem
Go to “MAP 1520: Power” on page 144.
1016 6034 Overcurrent or overvoltage problem with 2.5V in
third I/O subsystem
Go to “MAP 1520: Power” on page 144.
1016 6044 Overcurrent or overvoltage problem with 12.0V
in third I/O subsystem
Go to “MAP 1520: Power” on page 144.
1016 6054 Overcurrent or overvoltage problem with -12.0V
in third I/O subsystem
Go to “MAP 1520: Power” on page 144.
1016 6814 Overcurrent or overvoltage problem with 3.3V in
third I/O subsystem
Go to “MAP 1520: Power” on page 144.
1016 6824 Overcurrent or overvoltage problem with 5.0V in
third I/O subsystem
Go to “MAP 1520: Power” on page 144.
1016 6834 Overcurrent or overvoltage problem with 2.5V in
third I/O subsystem
Go to “MAP 1520: Power” on page 144.
1016 6844 Overcurrent or overvoltage problem with 12.0V
in third I/O subsystem
Go to “MAP 1520: Power” on page 144.
1016 6854 Overcurrent or overvoltage problem with -12.0V
in third I/O subsystem
Go to “MAP 1520: Power” on page 144.
1016 7017 Problem with fan 3 in third I/O subsystem in
primary rack
1. DCA-1
Location: U1.1-V1
2. Fan 3
Location: U1.1-F3
1016 7027 Problem with fan 4 in third I/O subsystem in
primary rack
1. DCA-2
Location: U1.1-V2
2. Fan 4
Location: U1.1-F4
1016 7117 Problem with fan 1 and fan 3 in third I/O
subsystem in primary rack
1. DCA-1
Location: U1.1-V1
2. Fans 1 and 3
Location: U1.1-F1 and U1.1-F3
1016 7127 Problem with fan 2 and fan 4 in third I/O
subsystem in primary rack
1. DCA-2
Location: U1.1-V2
2. Fans 2 and 4
Location: U1.1-F2 and U1.1-F4
364
Eserver
pSeries 670 Service Guide
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......