Error Code Description
Action/
Possible Failing FRU
101C F596 An N+1 boundary (DCA or fan) has dropped to
N-mode status in the processor subsystem,
location: U1.18
This is normally an informational message. It
should be accompanied by other error codes
that more precisely indicate where the failure is.
Examine the service processor error log. If there
are no other power-related error codes (in the
time frame in which this code was generated) in
the service processor error log, the FRU
indicated with this error code, if any, should be
replaced.
101C F5A6 An N+1 boundary (DCA or fan) has dropped to
N-mode status in the processor subsystem,
location: U1.18
This is normally an informational message. It
should be accompanied by other error codes
that more precisely indicate where the failure is.
Examine the service processor error log. If there
are no other power-related error codes (in the
time frame in which this code was generated) in
the service processor error log, the FRU
indicated with this error code, if any, should be
replaced.
101C xx11 Processor subsystem / DCA-1
U1.18-P1-V1
101C xx13 Seeprom (VPD) fault on processor subsystem
DCA-1
U1.18-P1-V1
101C xx15 Processor subsystem / DCA-1 cable fault
Go to “MAP 1520: Power” on page 144 with
these pairs of location codes:
1. U1.18-P1-V1/Q1 and U1.35-P1-X4/Q5
2. U1.18-P1-V1/Q2 and U1.35-P2-X4/Q5
101C xx21 Processor subsystem / DCA-2
U1.18-P1-V2
101C xx23 Seeprom (VPD) fault on processor subsystem
DCA-2
U1.18-P1-V2
101C xx25 Processor subsystem / DCA-2 cable fault
Go to “MAP 1520: Power” on page 144 with
these pairs of location codes:
1. U1.18-P1-V2/Q1 and U1.35-P1-X4/Q6
2. U1.18-P1-V2/Q2 and U1.35-P2-X4/Q6
101C xx31 Processor subsystem / DCA-3
U1.18-P1-V4
101C xx33 Seeprom (VPD) fault on processor subsystem
DCA -3
U1.18-P1-V4
101C xx35 Processor subsystem / DCA-3 cable fault
Go to “MAP 1520: Power” on page 144 with
these pairs of location codes:
1. U1.18-P1-V4/Q1 and U1.35-P1-X4/Q7
2. U1.18-P1-V4/Q2 and U1.35-P2-X4/Q7
101C xx41 Processor subsystem / DCA-4
U1.18-P1-V5
101C xx43 Seeprom (VPD) fault on processor subsystem
DCA-4
U1.18-P1-V5
101C xx45 Processor subsystem / DCA-4 cable fault
Go to “MAP 1520: Power” on page 144 with
these pairs of location codes:
1. U1.18-P1-V5/Q1 and U1.35-P1-X3/Q9
2. U1.18-P1-V5/Q2 and U1.35-P2-X3/Q9
101C xx51 Processor subsystem / DCA-5
U1.18-P1-V6
101C xx53 Seeprom (VPD) fault on processor subsystem
DCA-5
U1.18-P1-V6
Chapter 5. Error Code to FRU Index
391
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......