Error Code Description
Action/
Possible Failing FRU
450B 30C3 Memory subsystem and processor subsystem
tests detected fault in 32 GB or 64 GB CUoD
inner memory book
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
450B 30C6 Memory subsystem and processor subsystem
tests detected fault in 8 GB or 16 GB CUoD
outer memory book
Go to “MAP 1545: Outer L3 Module Problem
Isolation” on page 284.
450B 30CC Memory subsystem and processor subsystem
tests detected fault in 32 GB or 64 GB CUoD
outer memory book
Go to “MAP 1545: Outer L3 Module Problem
Isolation” on page 284.
450C 248B Memory subsystem and IPL detected fault in
operator panel
Operator panel
Location: U1.17-L1
450C 25C0 Memory subsystem and IPL detected fault in
system backplane
System backplane
Location: U1.18-P1
450C 25C1 Memory subsystem and IPL detected fault in
1.0 GHz clock card
Clock card
Location: U1.18-P1-X5
450C 25D9 Memory subsystem and IPL detected fault in L3
VPD card used with 1.1 GHz MCM and 1.3
GHz MCM
Go to “MAP 1548: Memory and Processor
Problem Isolation” on page 290.
450C 25E7 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
Go to “MAP 1548: Memory and Processor
Problem Isolation” on page 290.
450C 25E8 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
Go to “MAP 1548: Memory and Processor
Problem Isolation” on page 290.
450C 25F1 Memory subsystem and IPL detected fault in L3
VPD card used with 1.3 GHz MCM
Go to “MAP 1548: Memory and Processor
Problem Isolation” on page 290.
450C 25F9 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
Go to “MAP 1548: Memory and Processor
Problem Isolation” on page 290.
450C 269A Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
Go to “MAP 1548: Memory and Processor
Problem Isolation” on page 290.
450C 28B0 Memory subsystem and IPL detected fault in
I/O subsystem PCI backplane
I/O subsystem PCI backplane at location
specified in error code
450C 28B1 Memory subsystem and IPL detected fault in
I/O subsystem DASD backplane
I/O subsystem DASD backplane at location
specified in error code
450C 302A Memory subsystem and IPL detected fault in 8
GB memory book (inner)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253 to isolate the failing
component.
450C 302B Memory subsystem and IPL detected fault in 8
GB memory book (outer)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253 to isolate the failing
component.
450C 302C Memory subsystem and IPL detected fault in 32
GB memory book (inner)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253 to isolate the failing
component.
450C 302D Memory subsystem and IPL detected fault in 32
GB memory book (outer)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253 to isolate the failing
component.
450C 305A Memory subsystem and processor subsystem
tests detected fault in 8 GB memory book
(inner)
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
Chapter 5. Error Code to FRU Index
637
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......