Error Code Description
Action/
Possible Failing FRU
101A 0876 BPR 3A communications fault
Go to “MAP 1523: There Is a Bulk Power
Regulator (BPR) Communications Fault” on
page 152.
101A 0D06 350 volt bulk failure, BPA-A
Go to “MAP 1525: There Is a 350 Volt Bulk
Failure” on page 154.
101A 1C06 Cage airflow missing (temperature problem)
Go to “MAP 1527: An Airflow Loss Has Been
Detected” on page 160.
101A 3F06 Invalid I/O subsystem configurations
1. Verify that the I/O subsystems are properly
cabled.
Note:
If the service processor is hung, this
error code causes the service processor to
hang. Refer to “Resetting the Service
Processor” on page 758.
2. Call service support.
101A 7A56 IBF failure
Go to “MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure” on page 157.
101A 7A66 IBF failure
Go to “MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure” on page 157.
101A 7A76 IBF failure
Go to “MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure” on page 157.
101A 7A86 IBF 1A failure
Go to “MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure” on page 157.
101A 7A96 IBF 2A failure
Go to “MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure” on page 157.
101A 7AA6 IBF 3A failure
Go to “MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure” on page 157.
101A 7B56 IBF failure
Go to “MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure” on page 157.
101A 7B66 IBF failure
Go to “MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure” on page 157.
101A 7B76 IBF failure
Go to “MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure” on page 157.
101A 7B86 IBF 1A failure
Go to “MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure” on page 157.
101A 7B96 IBF 2A failure
Go to “MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure” on page 157.
101A 7BA6 IBF 3A failure
Go to “MAP 1526: There Is An Integrated Battery
Feature (IBF) Failure” on page 157.
101A CE16 BPC-BPC communication failure
1. Check the cable between the two BPCs;
reseat and look for bent pins.
2. Replace BPC-A, location: U1.35-P1-X4
3. Replace BPC-B, location: U1.35-P2-X4.
101A D216 BPA-BPA communication failure
Go to “MAP 1520: Power” on page 144 for
isolation.
Chapter 5. Error Code to FRU Index
371
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......