![IBM pSeries 670 Service Manual Download Page 386](http://html2.mh-extra.com/html/ibm/pseries-670/pseries-670_service-manual_4208211386.webp)
Error Code Description
Action/
Possible Failing FRU
1016 F526 An N+1 boundary (DCA or fan) has dropped to
N-mode status in the third I/O subsystem,
location: U1.1.
This is normally an informational message. It
should be accompanied by other error codes
that more precisely indicate where the failure is.
Examine the service processor error log. If there
are no other power-related error codes (in the
time frame in which this code was generated) in
the service processor error log, the FRU
indicated with this error code, if any, should be
replaced.
1016 xx11 third I/O subsystem in primary rack, DCA-1
U1.1-V1
1016 xx13 Seeprom fault on DCA-1 in third I/O subsystem
in primary rack
U1.1-V1
1016 xx15 Third I/O subsystem in primary rack, DCA-1,
cable fault
Go to “MAP 1520: Power” on page 144 with
these pairs of location codes:
1. U1.1-V1/Q1 and U1.35-P2-X3/Q5
2. U1.1-V1/Q2 and U1.35-P1-X3/Q5
1016 xx17 Problem with fan 1 and fan 3 in third I/O
subsystem in primary rack
1. DCA-1
Location U1.1–V1
2. Fan 1,
Location U1.1–F1
3. Fan 3,
Location U1.1–F3
1016 xx21 Third I/O subsystem in primary rack, DCA-2
U1.1-V2
1016 xx23 Seeprom fault on DCA-2 in third I/O subsystem
in primary rack
U1.1-V2
1016 xx25 Third I/O subsystem in primary rack, DCA-2,
cable fault
Go to “MAP 1520: Power” on page 144 with
these pairs of location codes:
1. U1.1-V2/Q1 and U1.35-P2-X3/Q6
2. U1.1-V2/Q2 and U1.35-P1-X3/Q6
1016 xx27 Problem with fan 2 and fan 4 in third I/O
subsystem in primary rack
1. DCA-2
Location U1.1–V2
2. Fan 2,
Location U1.1F2
3. Fan 4,
Location U1.1–F4
1016 xx31 Third I/O subsystem in primary rack, I/O
subsystem backplane 1 fault
U1.1-P1
1016 xx33 Seeprom fault on I/O subsystem backplane 1 in
third I/O subsystem in primary rack
U1.1-P1
1016 xx41 Third I/O subsystem in primary rack, I/O
subsystem backplane 2 fault
U1.1-P2
1016 xx43 Seeprom fault on I/O subsystem backplane 2 in
third I/O subsystem in primary rack
U1.1-P2
1016 xx51 Third I/O subsystem in primary rack, DASD
backplane 1 fault
U1.1-P3
1016 xx53 Seeprom fault on DASD backplane 1 in third I/O
subsystem in primary rack
U1.1-P3
366
Eserver
pSeries 670 Service Guide
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...