Error Code Description
Action/
Possible Failing FRU
1021 7027 Problem with fan 4 in first I/O subsystem in
second rack (I/O subsystem 5)
1. DCA-2
Location: U2.1-V2
2. Fan 4
Location: U2.1-F4
1021 7117 Problem with fan 1 and fan 3 in first I/O
subsystem in second rack (I/O subsystem 5)
1. DCA-1
Location: U2.1-V1
2. Fans 1 and 3
Location: U2.1-F1 and U2.1-F3
1021 7127 Problem with fan 2 and fan 4 in first I/O
subsystem in second rack (I/O subsystem 5)
1. DCA-2
Location: U2.1-V2
2. Fans 2 and 4
Location: U2.1-F2 and U2.1-F4
1021 B014 Overcurrent or overvoltage problem with 3.3V in
5th I/O subsystem
Go to “MAP 1520: Power” on page 144.
1021 B024 Overcurrent or overvoltage problem with 5.0V in
5th I/O subsystem
Go to “MAP 1520: Power” on page 144.
1021 B034 Overcurrent or overvoltage problem with 2.5V in
5th I/O subsystem
Go to “MAP 1520: Power” on page 144.
1021 B044 Overcurrent or overvoltage problem with 12.0V
in 5th I/O subsystem
Go to “MAP 1520: Power” on page 144.
1021 B054 Overcurrent or overvoltage problem with -12.0V
in 5th I/O subsystem
Go to “MAP 1520: Power” on page 144.
1021 B814 Overcurrent or overvoltage problem with 3.3V in
5th I/O subsystem
Go to “MAP 1520: Power” on page 144.
1021 B824 Overcurrent or overvoltage problem with 5.0V in
5th I/O subsystem
Go to “MAP 1520: Power” on page 144.
1021 B834 Overcurrent or overvoltage problem with 2.5V in
5th I/O subsystem
Go to “MAP 1520: Power” on page 144.
1021 B844 Overcurrent or overvoltage problem with 12.0V
in 5th I/O subsystem
Go to “MAP 1520: Power” on page 144.
1021 B854 Overcurrent or overvoltage problem with -12.0V
in 5th I/O subsystem
Go to “MAP 1520: Power” on page 144.
1021 BF06 Unable to resolve the chassis VPD in an I/O
subsystem
The chassis VPD in the I/O subsystem drawer
identified by the location code could not be
resolved. This may be an indication that more
than one FRU in the drawer was replaced during
a service action. If this is the case, reinstall the
original FRUs in the drawer, then replace the
FRUs one at a time.
If only one FRU was replaced and this error
code occurred, call service support.
1021 CD96 A power short has been detected in the DASD
subsystem in an I/O drawer.
Go to “MAP 1520: Power” on page 144.
1021 CDA6 A power short has been detected in the DASD
subsystem in an I/O drawer.
Go to “MAP 1520: Power” on page 144.
1021 CDB6 A power short has been detected in the DASD
subsystem in an I/O drawer.
Go to “MAP 1520: Power” on page 144.
394
Eserver
pSeries 670 Service Guide
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......