Error Code Description
Action/
Possible Failing FRU
1016 xx61 Third I/O subsystem in primary rack, DASD
backplane 2 fault
U1.1-P4
1016 xx63 Seeprom fault on DASD backplane 2 in third I/O
subsystem in primary rack
U1.1-P4
1016 xx71 Third I/O subsystem in primary rack, DASD
backplane 3 fault
U1.1-P5
1016 xx73 Seeprom fault on DASD backplane 3 in third I/O
subsystem in primary rack
U1.1-P5
1016 xx81 Third I/O subsystem in primary rack, DASD
backplane 4 fault
U1.1-P6
1016 xx83 Seeprom fault on DASD backplane 4 in third I/O
subsystem in primary rack
U1.1-P6
1017 1B17 Problem with fan 1 in fourth I/O subsystem (no
IBF installed) in primary rack
1. DCA-1
Location: U1.13-V1
2. Fan 1
Location: U1.13-F1
1017 1B27 Problem with fan 2 in fourth I/O subsystem (no
IBF installed) in primary rack
1. DCA-2
Location: U1.13-V2
2. Fan 2
Location: U1.13-F2
1017 1C06 Loss of airflow in fourth I/O subsystem, no IBF
location: U1.13
Go to “MAP 1527: An Airflow Loss Has Been
Detected” on page 160.
1017 6014 Overcurrent or overvoltage problem with 3.3V in
fourth I/O subsystem, no IBF
Go to “MAP 1520: Power” on page 144.
1017 6024 Overcurrent or overvoltage problem with 5.0V in
fourth I/O subsystem, no IBF
Go to “MAP 1520: Power” on page 144.
1017 6034 Overcurrent or overvoltage problem with 2.5V in
fourth I/O subsystem, no IBF
Go to “MAP 1520: Power” on page 144.
1017 6044 Overcurrent or overvoltage problem with 12.0V
in fourth I/O subsystem, no IBF
Go to “MAP 1520: Power” on page 144.
1017 6054 Overcurrent or overvoltage problem with -12.0V
in fourth I/O subsystem, no IBF
Go to “MAP 1520: Power” on page 144.
1017 6814 Overcurrent or overvoltage problem with 3.3V in
fourth I/O subsystem, no IBF
Go to “MAP 1520: Power” on page 144.
1017 6824 Overcurrent or overvoltage problem with 5.0V in
fourth I/O subsystem, no IBF
Go to “MAP 1520: Power” on page 144.
1017 6834 Overcurrent or overvoltage problem with 2.5V in
fourth I/O subsystem, no IBF
Go to “MAP 1520: Power” on page 144.
1017 6844 Overcurrent or overvoltage problem with 12.0V
in fourth I/O subsystem, no IBF
Go to “MAP 1520: Power” on page 144.
1017 6854 Overcurrent or overvoltage problem with -12.0V
in fourth I/O subsystem, no IBF
Go to “MAP 1520: Power” on page 144.
1017 7017 Problem with fan 3 in fourth I/O subsystem (no
IBF installed) in primary rack
1. DCA-1
Location: U1.13-V1
2. Fan 3
Location: U1.13-F3
Chapter 5. Error Code to FRU Index
367
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......