Error Code Description
Action/
Possible Failing FRU
B1xx 4633
Cont’d
1. Wait 10 minutes after the system has
reached the AIX prompt. Examine the AIX
error log for new B1xx 4633 errors with the
word 13 values (in bytes 68 and 69 in the
error log entry). If there are no B1xx 4633
errors with matching time stamps, the
SPCN down load was successful. If the
download failed again (there is another
B1xx 4633 error in the AIX error log with the
correct time stamp), do the following:
a. Power down the system.
b. Collect the service processor error log
data for the B1xx 4633 error (see 2 on
page 685).
c. Collect the SPCN trace data (see 3 on
page 685).
d. Contact service support. For all other
values of word 13, or bytes 68 and 69,
do the following:
1) Check for system firmware updates.
Apply if available.
2) Call service support.
B1xx 4634 SPCN Loop Fault
1. Check SPCN cabling.
2. Go to “MAP 1542: I/O Problem Isolation” on
page 261.
B1xx 4635 AC input was removed, then restored.
Informational message. Look at the service
processor error log for additional error codes
relating to loss of ac power to the system.
B1xx 4636 System is running on battery back-up power
Informational message.
B1xx 4643 Problem when turning on the identify LED of a
FRU
1. Use the location code that was provided
with the original error code to isolate and
replace the failing device.
2. If a problem persists, go to “MAP 154A: I2C
Bus Problem Isolation” on page 301.
B1xx 4644 I2C connection failure
1. Check for system firmware updates.
2. Primary I/O book
Location: U1.18-P1-H2
B1xx 4645 I2C (non-processor) VPD system fault
Go to “MAP 1540: Problem Isolation
Procedures” on page 253.
B1xx 4646 Vital product data (VPD) acquisition failure
1. Check for system firmware updates.
2. Primary I/O book
Location: U1.18-P1-H2
B1xx 4647 Machine type and model fields missing or
invalid in system VPD
The machine type and model fields must be
rewritten. Call service support.
B1xx 4648 Processor subsystem backplane VPD or power
source problem
Go to “MAP 1540: Problem Isolation
Procedures” on page 253.
B1xx 4650 System processor failure (all processors reset).
Reboot the system in slow mode to isolate the
problem.
B1xx 4651 CPU GARD VPD on MCM 0
U1.18-P1-C1 and U1.18-P1-H2.3
686
Eserver
pSeries 670 Service Guide
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......