Error Code Description
Action/
Possible Failing FRU
101B DC16 External UPS: battery not low (informational
message)
Informational message. If a problem is
suspected:
1. Verify the cabling between the UPS and the
BPCs.
2. Refer to the manufacturer’s documentation
for the UPS.
3. Call service support.
101B DC56 Informational message about the IBF.
Informational message.
101B DC66 Informational message about the IBF.
Informational message.
101B DC76 Informational message about the IBF.
Informational message.
101B DD16 External UPS: bypass ended (informational
message)
Informational message. If a problem is
suspected:
1. Verify the cabling between the UPS and the
BPCs.
2. Refer to the manufacturer’s documentation
for the UPS.
3. Call service support.
101B DF16 Problem with external UPS: UPS failure
1. Verify the cabling between the UPS and the
BPCs.
2. Refer to the manufacturer’s documentation
for the UPS.
3. Call service support.
101B E106 Critical logic over temperature
Go to “MAP 1528: There Is A Processor
(Critical/Warning) Overtemperature Fault” on
page 162.
101B E206 Ambient room temperature too high
1. The ambient room temperature has reached
a warning level or a critical level. Ask the
customer to correct the room temperature
problem.
2. Call service support.
101B F4x6 Hardware configuration does not support
N-mode power
Call service support.
101B F806 BPC B: loss of ac power or phase missing
Go to “MAP 152a: Loss of ac Power or Phase
Missing” on page 165.
101B F906 BPC B: loss of ac power or phase missing
Go to “MAP 152a: Loss of ac Power or Phase
Missing” on page 165.
101B FA06 BPC B: loss of ac power or phase missing
Go to “MAP 152a: Loss of ac Power or Phase
Missing” on page 165.
101B FDB6 BPC B: open room EPO switch has been
detected
Go to “MAP 1524: An Open Room EPO Switch
Has Been Detected From One Side” on
page 152.
101B FE06 UEPO switch on BPC B is in the bypass position Go to “MAP 1522: UEPO Switch On The BPC Is
In The Bypass Position” on page 151.
101B FE16 UEPO switch on BPC B is in the bypass position Go to “MAP 1522: UEPO Switch On The BPC Is
In The Bypass Position” on page 151.
101B FE56 BPR 1B communications fault
Go to “MAP 1523: There Is a Bulk Power
Regulator (BPR) Communications Fault” on
page 152.
380
Eserver
pSeries 670 Service Guide
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......