Error Code Description
Action/
Possible Failing FRU
4508 305A Memory subsystem and processor subsystem
tests detected fault in 8 GB memory book
(inner)
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
4508 305B Memory subsystem and processor subsystem
tests detected fault in 8 GB memory book
(outer)
Go to “MAP 1545: Outer L3 Module Problem
Isolation” on page 284.
4508 305C Memory subsystem and other bus tests
detected fault in 4 GB inner memory book
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
4508 305D Memory subsystem and other bus tests
detected fault in 4 GB outer memory book
Go to “MAP 1545: Outer L3 Module Problem
Isolation” on page 284.
4508 305E Memory subsystem and other bus tests
detected fault in 16 GB inner memory book
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
4508 305F Memory subsystem and other bus tests
detected fault in 16 GB outer memory book
Go to “MAP 1545: Outer L3 Module Problem
Isolation” on page 284.
4508 307A Memory subsystem and processor subsystem
tests detected fault in 4 GB inner memory book
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
4508 307B Memory subsystem and processor subsystem
tests detected fault in 8 GB inner memory book
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
4508 307C Memory subsystem and processor subsystem
tests detected fault in 16 GB inner memory
book
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
4508 307D Memory subsystem and processor subsystem
tests detected fault in 16 GB inner memory
book
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
45084 307E Memory subsystem and processor subsystem
tests detected fault in 16 GB inner memory
book
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
4508 308A Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
Go to “MAP 1545: Outer L3 Module Problem
Isolation” on page 284.
4508 308B Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
Go to “MAP 1545: Outer L3 Module Problem
Isolation” on page 284.
4508 308C Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
Go to “MAP 1545: Outer L3 Module Problem
Isolation” on page 284.
4508 308D Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
Go to “MAP 1545: Outer L3 Module Problem
Isolation” on page 284.
4508 308E Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
Go to “MAP 1545: Outer L3 Module Problem
Isolation” on page 284.
4508 30BD Memory subsystem and processor subsystem
tests detected fault in 8 GB or 16 GB CUoD
inner memory book
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
4508 30C3 Memory subsystem and processor subsystem
tests detected fault in 32 GB or 64 GB CUoD
inner memory book
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
4508 30C6 Memory subsystem and processor subsystem
tests detected fault in 8 GB or 16 GB CUoD
outer memory book
Go to “MAP 1545: Outer L3 Module Problem
Isolation” on page 284.
4508 30CC Memory subsystem and processor subsystem
tests detected fault in 32 GB or 64 GB CUoD
outer memory book
Go to “MAP 1545: Outer L3 Module Problem
Isolation” on page 284.
Chapter 5. Error Code to FRU Index
631
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......