Error Code Description
Action/
Possible Failing FRU
4609 527A CUoD capacity card fault
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
4609 527C CUoD capacity card fault
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
460A 248B I/O subsystem and self-tests detected fault in
operator panel
Operator panel
Location: U1.17-L1
460A 25C0 I/O subsystem and self-tests detected fault in
system backplane
System backplane
Location: U1.18-P1
460A 25C1 I/O subsystem and self-tests detected fault in
1.0 GHz clock card
Clock card
Location: U1.18-P1-X5
460A 2738 I/O subsystem and self-tests detected fault in
I/O book 1, 3, or 4
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
460A 273C I/O subsystem and self-tests detected fault in
primary I/O book - Slot 0
Primary I/O book - Slot 0
Location: U1.18-P1-H2
460A 273D I/O subsystem and processor subsystem tests
detected fault in primary I/O book - Slot 0
Primary I/O book - Slot 0
Location: U1.18-P1-H2
460A 2776 I/O subsystem and processor subsystem tests
detected fault in I/O book 1, 3, or 4
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
460A 2806 I/O subsystem and processor subsystem tests
detected fault in I/O book 1, 3, or 4
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
460A 28B0 I/O subsystem and self-tests detected fault in
I/O subsystem PCI backplane
I/O subsystem PCI backplane at location
specified in error code
460A 28B1 I/O subsystem and self-tests detected fault in
I/O subsystem DASD backplane
I/O subsystem DASD backplane at location
specified in error code
652
Eserver
pSeries 670 Service Guide
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......