Error Code Description
Action/
Possible Failing FRU
20EE 0022 The
boot-device
environment variable
contained an entry that exceeded 255
characters in length
If this error occurs during the installation of
AIX via a process called
NIM push
, the
set_bootlist
attribute may not have been set
correctly on the NIM master. See the
AIX 5.2
Installation Guide and Reference
, order
number SC23-4389, for more information.
If this error occurs at any other time, complete
the following steps:
1. Check for platform firmware updates.
Apply if available.
2. Call service support.
20EE 0100 Fcode resident on an I/O adapter is not
supported on this system
Informational message. The adapter’s Fcode
driver is not supported on this system. IBM
may produce a compatible driver in the future,
but does not guarantee one. Additional
information may be available from service
support.
This error code only affects boot-time
operation, not the adapter’s functionality under
the operating system.
20FB 0010 Failed to find keyword offset of SPCN
configuration table in NVRAM.
Call service support.
20FB 0020 Invalid SPCN configuration table flag before
SPCN table update.
Call service support.
20FC 0020 Failed to retrieve power, package, and/or
cooling VPD via SPCN for the corresponding
subsystem. Service processor mailbox failed
to get VPD
1. Check RIO cable connection.
2. Check for system firmware updates.
3. Replace the part specified by the location
code.
20FC 0021 Failed to retrieve power, package, and/or
cooling VPD via SPCN for the subsystem.
Service processor mailbox failed to get power,
packaging, and cooling device VPD
1. Check RIO cable connection.
2. Check for system firmware updates.
3. Replace the part specified by the location
code.
20FC 0030 Damaged power, packaging, and/or cooling
device VPD format in SPCN configuration
table
1. Check for system firmware updates.
2. Replace the part specified by the location
code.
20FF 0001 Problem with VPD
1. Replace the part indicated by the location
code.
2. If no location code is shown with the error
code, call service support.
20FF0010 Invalid VPD (defect ROM structure for PCI)
1. Replace the part specified by the location
code.
2. If no location code is shown with the error
code, call service support.
20FF0020 Invalid VPD (checksum mismatch)
1. Replace the part specified by the location
code.
2. If no location code is shown with the error
code, call service support.
Chapter 5. Error Code to FRU Index
425
Summary of Contents for pSeries 670
Page 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 2: ......
Page 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Page 12: ...x Eserver pSeries 670 Service Guide...
Page 16: ...xiv Eserver pSeries 670 Service Guide...
Page 18: ...xvi Eserver pSeries 670 Service Guide...
Page 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Page 718: ...698 Eserver pSeries 670 Service Guide...
Page 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Page 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Page 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Page 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Page 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Page 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Page 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Page 986: ...966 Eserver pSeries 670 Service Guide...
Page 990: ...970 Eserver pSeries 670 Service Guide...
Page 1018: ...998 Eserver pSeries 670 Service Guide...
Page 1020: ...1000 Eserver pSeries 670 Service Guide...
Page 1028: ...1008 Eserver pSeries 670 Service Guide...
Page 1031: ......