manualshive.com logo in svg
background image

User's Manual

 

Revision 1.0

a

S

UPER

S

ERVER

®

5028TK-HTR

5028TK-HTTR

Содержание SUPERSERVER 5028TK-HTR

Страница 1: ...User s Manual Revision 1 0a SUPERSERVER 5028TK HTR 5028TK HTTR ...

Страница 2: ...f any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commerci...

Страница 3: ... necessary to install the SuperServer 5028TK HTR HTTR into a rack and check out the server configuration prior to powering up the system If your server was ordered without processor and memory components this chapter will refer you to the appropriate sections of the manual for their installation Chapter 3 System Interface Refer here for details on the system interface which includes the functions ...

Страница 4: ...u should follow the procedures given in this chapter when installing removing or reconfiguring hard drives and when replacing system power supply units and cooling fans Chapter 7 BIOS The BIOS chapter includes an introduction to BIOS and provides detailed information on running the CMOS Setup Utility Appendix A System Specifications Appendix B UEFI BIOS Recovery ...

Страница 5: ...v SUPERSERVER 5028TK HTR HTTR User s Manual Notes ...

Страница 6: ... System Power 1 7 Hard Drive Backplane Drives 1 7 Chapter 2 Server Installation 2 1 Overview 2 1 2 2 Unpacking the System 2 1 2 3 Preparing for Setup 2 1 2 4 Warnings and Precautions 2 2 Choosing a Setup Location 2 2 Rack Precautions 2 2 Server Precautions 2 2 Rack Mounting Considerations 2 3 Ambient Operating Temperature 2 3 Reduced Airflow 2 3 Mechanical Loading 2 3 Circuit Overloading 2 3 Relia...

Страница 7: ...6 Equipment Installation 4 8 Restricted Area 4 9 Battery Handling 4 10 Redundant Power Supplies 4 12 Backplane Voltage 4 13 Comply with Local and National Electrical Codes 4 14 Product Disposal 4 15 Hot Swap Fan Warning 4 16 Power Cable and AC Adapter 4 18 Chapter 5 Advanced Serverboard Setup 5 1 Handling the Serverboard 5 1 Precautions 5 1 Unpacking 5 1 5 2 Connecting Cables 5 2 Connecting Data C...

Страница 8: ...the Backplane 6 8 Removing the Backplane 6 8 Installing the Backplane 6 10 6 8 Installing the Serverboard 6 11 I O Shield 6 11 Permanent and Optional Standoffs 6 11 6 9 Adapter Card Replacement 6 13 Installing an Add on Card 6 14 6 10 Drive Bay Installation Removal 6 15 Accessing the Drive Bays 6 15 6 11 Power Supply 6 19 Power Supply Replacement 6 19 Chapter 7 BIOS 7 1 Introduction 7 1 Starting B...

Страница 9: ...7 7 Boot Settings 7 43 7 8 Save Exit 7 45 Appendix A System Specifications Appendix B UEFI BIOS Recovery Instructions ix Table of Contents ...

Страница 10: ...x Notes SUPERSERVER 5028TK HTR HTTR User s Manual ...

Страница 11: ...r 1U passive CPU heatsinks SNK P0060P Four mylar air shrouds MCP 310 21704 0B Four 8 cm cooling fans FAN 0162L4 SATA SAS Backplane Four HD backplanes BPN ADP 6SATA3 One SAS backplane HDD BPN SAS3 827HQ Twelve hot swap 3 5 HDD trays MCP 220 00075 0B Eight riser cards 4x RSC R1UTP E16R and 4x RSC P 6 One rackmount rail kit MCP 290 00053 0N Note For your system to work properly please follow the link...

Страница 12: ...ed processors www supermicro com Memory The K1SPi K1SPi T has six DIMM slots supporting up to 384 GB of RDIMM Registered DIMM DDR4 2400 ECC memory See Chapter 5 for details Note Check the Supermicro website www supermicro com for the latest memory support information SATA The 5028TK HTR uses a controller integrated into the PCH C612 chipset to support eight SAS3 hard drives per node RAID 0 1 and 1...

Страница 13: ...hassis includes a redundant high efficiency 80 plus Platinum certified power supply rated at 2000 Watts one active and one backup power supply module In the event your power supply fails replacement is simple and can be accomplished without tools Front Control Panel The SC827HQ R2K04BP2 chassis includes four front panels on the handles of the chassis which control each of the nodes Each control pa...

Страница 14: ...ode that directs the airflow where cooling is needed on each serverboard Always use the air shroud included with each serverboard Mounting Rails The SC827HQ includes a set of quick release rails and can be placed in a rack for secure storage and use To setup your rack follow the step by step instructions included in Chapter 2 ...

Страница 15: ... NC_SI RJ45 LPC LAN2 MDI LAN1 MDI SPI MDI SXB3 DDR4 1 2 3 PCIe X16 G3 Intel Processor PCI E X16 DMI2 4GB s DMI2 PCI E X4 G2 LAN i350 X540 1 Port 80 2 USB 2 0 PCI E X1 G2 PCH USB 3 0 TPM HEADER USB SPI BIOS 3 SXB2 6 0 Gb S SATA port 0 5 SPI LAN3 PHY 6 0 Gb S S SATA port 2 3 RGRMII SATA DOM RJ45 H W Monitoring Temp Sensor FAN PWM BMC AST2400 COM1 Header VGA CONN BMC Boot Flash DDR3 LPC SATA 5 4 DDR4...

Страница 16: ...o com Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support Website www supermicro nl Asia Pacific Address Super Micro Computer Inc 3F No 150 Jian 1st Rd Zhonghe Dist New Taipei City 235 Taiwan...

Страница 17: ...a stop when a node is fully installed If too much force is used when inserting a node this pin may break off Take care to slowly slide a node in until you hear the click of the locking tab seating itself System Power Dual 2000 Watt power supplies are used to provide the power for all four serverboards Each serverboard however can be shut down independently of the other with the power button on its...

Страница 18: ...1 8 SUPERSERVER 5028TK HTR HTTR User s Manual Notes ...

Страница 19: ...aged in any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the SuperServer 5028TK HTR HTTR It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated You will also need it placed near a g...

Страница 20: ... rack installation stabilizers should be attached to the rack In multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more simultaneously may cause the rack to become unstable Server Precautions Review the electrical and general safety precautio...

Страница 21: ...sible overloading of circuits might have on overcurrent protection and power supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable Ground A reliable ground must be maintained at all times To ensure this the rack itself should be grounded Particular attention should be given to power supply connections other than the direct conne...

Страница 22: ... includes two rail assemblies in the rack mounting kit Each assembly consists of two sections an inner fixed chassis rail that secures directly to the server chassis and an outer fixed rack rail that secures directly to the rack itself Figure 2 1 Figure 2 1 Separating the Rack Rails Separating the Inner and Outer Rails 1 Locate the rail assembly in the chassis packaging 2 Extend the rail assembly ...

Страница 23: ... Rails Figure 2 2 1 Place the inner rail extensions on the side of the chassis aligning the hooks of the chassis with the rail extension holes Make sure the extension faces outward just like the pre attached inner rail 2 Slide the extension toward the front of the chassis 3 Secure the chassis with 2 screws as illustrated Repeat steps for the other inner rail extension 1 1 1 2 1 3 1 3 Slide rail mo...

Страница 24: ...r Rails to the Rack Figure 2 3 1 Secure the back end of the outer rail to the rack using the screws provided 2 Press the button where the two outer rails are joined to retract the smaller outer rail 3 Hang the hooks of the rails onto the rack holes and if desired use screws to secure the front of the outer rail onto the rack 4 Repeat steps 1 3 for the remaining outer rail Figure 2 3 Assembling the...

Страница 25: ...he outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has been pushed completely into the rack it should click into the locked position 4 Optional screws may be used to secure the to hold the front of the chassis to the rack Note The figure above is for illustration purposes only Always install servers to the bottom of the ...

Страница 26: ...2 8 SUPERSERVER 5028TK HTR HTTR User s Manual Notes ...

Страница 27: ...the drive carriers to keep you constantly informed of the overall status of the system SC827HQ models include four front panels on the handles of the chassis which control each of the systems This chapter explains the meanings of all LED indicators and the appropriate response you may need to take Figure 3 1 Control Panel ...

Страница 28: ... system This section explains what each LED indicates when illuminated and any corrective action you may need to take Overheat This LED is illuminated when an overheat condition occurs A solid red LED indicates an overheat condition in the system A flashing red LED which flashes in one second intervals indicates a fan failure A flashing red LED which flashes in four second interfals indicates a po...

Страница 29: ...minated this green LED on the front of the SATA drive carrier indicates drive activity A connection to the SATA backplane enables this LED to blink on and off when that particular drive is being accessed Red The red LED to indicate an SATA drive failure If one of the SATA drives fail you should be notified by your system management software SAS Drives This server system does not support SAS drives...

Страница 30: ...SUPERSERVER 5028TK HTR HTTR User s Manual 3 4 Notes ...

Страница 31: ... configuring components in the Supermicro chassis These warnings may also be found on our web site at http www supermicro com about policies safety_information cfm Warning Definition Warning This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard ...

Страница 32: ...á el número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo GUARDE ESTAS INSTRUCCIONES IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d avertissement indique un danger Vous vous trouvez dans une situation pouvant entraîner des blessures ou des dommages corporels Avant de travailler sur un équipement soyez conscient des dangers liés aux ...

Страница 33: ... aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE INSTRUCTIES ً ف اًك أى ٌوكي حالة ً ف تتسبب اصابة جسذٌة الزهز هذا ًٌ ٌع خطز ...

Страница 34: ...romquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación Attention Avant de brancher le système sur la source d alimentation consulter les directives d installation ال إرشادات اقر تركيب توصيل قبل إلى النظام للطاقة مصدر לקרוא יש למקור המערכת חיבור לפני התקנה הוראות את מתח 시스템을 전원에 연결하기 전에 설치 안내를 읽어주십시오 Waarsc...

Страница 35: ...äude ein Kurzschluss bzw Überstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A beträgt Advertencia Este equipo utiliza el sistema de protección contra cortocircuitos o sobrecorrientes del edificio Asegúrese de que el dispositivo de protección no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circ...

Страница 36: ...べてのソースから切断され 電源コードは電源モジュールから取り 外す必要があります 警告 在你打开机箱并安装或移除内部器件前 必须将系统完全断电 并移除电源线 警告 在您打開機殼安裝或移除內部元件前 必須將系統完全斷電 並移除電源線 경고 이 제품은 전원의 단락 과전류 방지에 대해서 전적으로 건물의 관련 설비에 의존합니다 보호장치의 정격이 반드시 250V 볼트 20A 암페어 를 초과하지 않도록 해야 합니다 Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging overspanning van uw electrische installatie Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 22...

Страница 37: ... sources de puissance ainsi que de son cordon d alimentation secteur avant d accéder à l intérieur du chassis pour installer ou enlever des composants de systéme חשמלי ניתוק מפני אזהרה אזהרה החשמל מקורות מכל המערכת את לנתק יש להסיר ויש מהספק החשמלי כבל את התקנ לצורך המארז של הפנימי לחלק גישה לפני ת הסר או ת רכיבים فصم يجب اننظاو جميع من مصادر انطاقت وإزانت انكهرباء سهك من وحدة امداد انطاقت قبم إنى...

Страница 38: ...n dieser Ausrüstung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo Attention Il est vivement recommandé de confier l installation le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés אזהרה רש בלבד מוסמך צוות את להחליף להתקין אי הציוד עבור שירות לתת...

Страница 39: ...t beschränktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich Advertencia Esta unidad ha sido diseñada para instalación en áreas de acceso restringido Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial cerradura con llave u otro medio ...

Страница 40: ...告 電池更換不當會有爆炸危險 請使用製造商建議之相同或功能相當的電池更換原有 電池 請按照製造商的說明指示處理廢棄舊電池 מוגבלת גישה עם אזור אזהרה בעזרת ניתנת הגישה גישה הגבלת בהם שיש באזורים היחידה את להתקין יש וכד מנעול מפתח בלבד אבטחה כלי تخصيص انىحذة هذه ٍ ف نتركُبها مناطق محظورة تم انىص َمكن ً إن ىل منطقت محظورة فقط استخذاو خالل من خاصت أداة أو ٌ أ نال أخري وسُهت مألما ومفتاح قفم 경고 이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다 특수도구 잠금 장치 및 키 또는 기타 보안 수단을 통해서만 접근 제한...

Страница 41: ...ipo o el equivalente recomendado por el fabricante Desechar las baterías gastadas según las instrucciones del fabricante אזהרה סכנת קיימת פיצוץ תקינה לא בדרך והוחלפה במידה הסוללה של להחליף יש בסוג הסוללה את מ התואם חברת מומל יצרן צת הסוללות סילוק המשומשות לבצע יש היצרן הוראות לפי خطر هناك من اسحبذال حالة في انفجار البطارية صحيحة غير بطريقة فعليل البطارية اسحبذال فقط النىع بنفس يعادلها ما أو مما أو...

Страница 42: ...hr haben Um sicherzustellen dass der Einheit kein trom zugeführt wird müssen alle Verbindungen entfernt werden Advertencia Puede que esta unidad tenga más de una conexión para fuentes de alimentación Para cortar por completo el suministro de energía deben desconectarse todas las conexiones Attention Cette unité peut avoir plus d une connexion d alimentation Pour supprimer toute tension et tout cou...

Страница 43: ...ten auf der Rückwandplatine gefährliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema está en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise قد لهذا يكون ال جهاز اتصاالت عدة بوحدات الطاقة امداد إزالة يجب االتصاالت كافة لعسل ال وحدة عن الكهرباء 경고 이 장치에는 한 개 이상의 전원 공급 단자가 연결되어 있을 수 있습니다 이 장치에 전원을 차단하기 위해서는 모든 연결 단자를 제거해야...

Страница 44: ...كهزبائي التيار على المىجىدة أوالطاقة اللىحة يكىن عندما النظام يعمل عند حذرا كه خدمة الجهاس هذا 경고 시스템이 동작 중일 때 후면판 Backplane 에는 위험한 전압이나 에너지가 발생 합니다 서비스 작업 시 주의하십시오 Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden tijdens het onderhoud האחורי בפנל מתח אז הרה במהלך להיזהר יש המערכת תפעול בזמן האחורי בפנל מתח סכ...

Страница 45: ... התקנת והארציים המקומיים החשמל לחוקי תואמת להיות חייבת הציוד المعدات تركيب الكهربائية لل يمتثل أن يجب قىاويه والىطىية المحلية المتعلقة بالكهرباء Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Attention L équipement doit être installé conformément aux normes électriques nationales et locales 경고 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다 Waarschuwing Bi...

Страница 46: ...t Swap Fan Warning Warning The fans might still be turning when you remove the fan assembly from the chassis Keep fingers screwdrivers and other objects away from the openings in the fan assembly s housing ファン ホッ トスワップの警告 シャーシから冷却ファン装置を取り外した際 ファンがまだ回転している可能性があり ます ファンの開口部に 指 ドライバー およびその他のものを近づけないで下さい 警告 המוצר סילוק אזהרה ו להנחיות בהתאם להיות חייב זה מוצר של סופי סילוק המדינה חוקי النهائي التخلص م...

Страница 47: ...品太靠近风扇 警告 當您從機架移除風扇裝置 風扇可能仍在轉動 小心不要將手指 螺絲起子和其他 物品太靠近風扇 Warnung Die Lüfter drehen sich u U noch wenn die Lüfterbaugruppe aus dem Chassis genommen wird Halten Sie Finger Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt Advertencia Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y ...

Страница 48: ... 材或适配器可能会引起故障或火灾 除了Supermicro所指定的产品 电气用品和材 料安全法律规定禁止使用未经UL或CSA认证的线材 线材上会显示UL CSA符号 警告 安裝此產品時 請使用本身提供的或指定的連接線 電源線和電源適配器 使用其它線 材或適配器可能會引起故障或火災 除了Supermicro所指定的產品 電氣用品和材 料安全法律規定禁止使用未經UL或CSA認證的線材 線材上會顯示UL CSA符號 Warnung Bei der Installation des Produkts die zur Verfügung gestellten oder benannt Anschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter kann zu einer Fehlfunktion oder ...

Страница 49: ...sur le code pour tous les autres appareils électriques que les produits désignés par Supermicro seulement ומתא חשמליים מ י AC אזהרה ומתאמים ספקים בכבלים להשתמש יש המוצר את מתקינים כאשר AC אשר או לתקלה לגרום יכול אחר מתאם או כבל בכל שימוש כך לשם וסופקו נועדו בט וחוקי חשמל במכשירי שימוש חוקי פי על חשמלי קצר איסור קיים יחות ב המוסמכים בכבלים להשתמש UL ב או CSA של קוד עליהם מופיע כשאר UL CSA אחר חשמלי...

Страница 50: ... kabels stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of CSA gecertificeerde kabels die UL of CSA die op de code voor andere elektrische apparaten dan de producten die door Supermicro alleen ...

Страница 51: ... center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a grounded wrist strap designed to prevent Electrostatic Discharge ESD Touch a grounded metal object before removing any board from its antistatic bag Handle a board by its edges only do not touch its components peripheral chips m...

Страница 52: ...ect any of these cables you should take care to reroute them as they were originally after reconnecting them make sure the red wires connect to the pin 1 locations If you are configuring the system keep the airflow in mind when routing the cables 5 3 Rear I O Ports See Figure 5 1 below for the and locations of the various rear I O ports and the UID switch 2 1 5 3 4 6 7 Rear I O Ports 1 GLAN Port 1...

Страница 53: ...not attempt to remove or modify these components other than for adjustments specifically outlined in this manual Making other adjustments to these components risks damaging the system and voiding the system warranty If you believe there is a hardware problem with one of these components please contact Supermicro s technical support team or your service contact if you have purchased a service packa...

Страница 54: ...ory that has been tested on the K1SPi K1SPi T serverboard For best performance use memory modules of the same type and speed in the same bank Memory Support The K1SPi K1SPi T has six DIMM slots to support up to 384 GB of RDIMM Registered DIMM DDR4 2400 ECC memory Note Check the Supermicro website www supermicro com for the latest memory support information Figure 5 3 DIMM Installation Release Tab ...

Страница 55: ... HTR HTTR includes one preinstalled riser card per node designed specifically for use in the SC827HQ R2K04BP2 2U rackmount chassis The RSCR1UTP E16R riser supports a single PCI E 3 0 x16 card on the right side of the system when viewed from the rear Installing an Expansion Card 1 After powering down the system remove the PCI slot shield 2 Fully seat the card into the slot pushing down with your th...

Страница 56: ... BIOS LICENSE JF1 JHFI1 UID_LED1 JTPM1 SXB3 SXB1 BT1 JUSB_A1 JUSB_A2 JBT1 JSTBY1 LE2 LEDM1 LED2 JPB1 JVRM1 JPG1 JVRM2 JBR1 JPL1 JWD1 JLAN2 JUSB1 JLAN1 S SATA3 SXB2 CPU PCI E 3 0 X 4 SXB3 PCI E 3 0 X 16 SXB1 CPU PCI E 3 0 X 16 SATA DOM POWER USB3 3 0 USB2 3 0 USB0 1 3 0 IPMI_LAN LAN2 I SATA0 5 UID SW S SATA2 SATA DOM POWER DIMMC1 DIMMB1 DIMMA1 VGA CMOS CLEAR BMC FLASH BATTERY PCH XDP CD COM1 JPME2 ...

Страница 57: ...bric Interface HFI Sideband Connection Header JPTM1 TPM Trusted Platform Module Port 80 JSTBY1 P5V 5V Standby Power Connector LAN1 LAN2 Gigabit GLAN Ethernet Port K1SPi 10G LAN TLAN Ethernet Port K1SPi T IPMI LAN Dedicated IPMI LAN Port SXB1 CPU PCI E 3 0 x16 Slot for S SATA0 1 support with proprietary riser card only SXB2 CPU PCI E 3 0 x4 Slot for I SATA0 5 support with proprietary riser card onl...

Страница 58: ...11 No Connection Add on Card Connector Pin Definitions JF1 Pin Definition Pin Definition P1 P12V_IN P8 Ground P2 P12V_IN P7 Ground P3 P12V_IN P6 Ground P4 P12V_IN P5 Ground Ethernet Port IPMI LAN Two Ethernet ports LAN1 LAN2 are located on the rear I O panel These LAN ports provide Gigabit GbE LAN support on the K1SPi and 10 Gigabit 10GbE LAN support on the K1SPi T In addition a dedicated IPMI LAN...

Страница 59: ...3 8 LAD 2 9 3 3V 10 LAD1 11 LAD0 12 GND 13 SMB_CLK 14 SMB_DAT 15 3V_DUAL 16 SERIRQ 17 GND 18 CLKRUN X 19 LPCPD 20 LDRQ X Unit Identifier Switch A Unit Identifier UID switch is located next to the VGA port on the I O backpanel and a rear UID LED UID_LED1 is located at next to the UID switch on the motherboard When the user presses the UID switch the UID LED will be turned on Press the UID switch ag...

Страница 60: ...BT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To Clear CMOS 1 First power down the system and unplug the power cord s It is also recommended that you remove the onboard battery from the serverboard 2 With the power disconnected short the CMOS pads with a metal object such as a...

Страница 61: ...C See the table on the right for jumper settings BMC Enable Jumper Settings Jumper Setting Definition Pins 1 2 BMC Enabled Pins 2 3 BMC Disabled Manufacturer Mode Select Close pins 2 and 3 of JPME2 to bypass SPI flash security and force the system to operate in the Manufacturer Mode which allows the user to flash the system firmware from a host server for system setting modifications See the table...

Страница 62: ... When this LED is blinking BMC is functioning normally See the table at right for more information LAN LEDs The onboard LAN1 LAN2 ports are located on the IO backpanel Each Ethernet LAN port has two LEDs The green LED on the right indicates activity The Link LED on the left may be green amber or off to indicate the speed of the connection See the tables below for more information LAN Speed LED K1S...

Страница 63: ...rt of I SATA 0 5 connections is located at SXB2 on the motherboard This PCI E slot is supported by the CPU Refer to the moth erboard layout for the locations S SATA 2 3 Super DOM Connectors S SATA2 and S SATA3 supported by Intel PCH S SATA controller provide SATA 3 0 connections These yellow connectors have power pins built in and can be used with Supermicro SuperDOM Disk on Module devices Supermi...

Страница 64: ...ttery in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly Figure 5 5 Installing the Onboard Battery OR ...

Страница 65: ...em very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing any board from its antistatic bag Handle a board by its edges only do not touch its components peripheral chips memory modules or gold contacts When handling chips or mod...

Страница 66: ...front of the chassis The LEDs inform you of system status See Chapter 3 for details on the LEDs and the control panel buttons SATA Drives 12 Control Panel Control Panel Control Panel Control Panel Power Supplies USB Ports UID Switch LED VGA Port LAN Ports IPMI LAN Port Low Profile PCI E Slot Node1 Node2 Node3 Node4 Note also see Figure 6 13 ...

Страница 67: ... cooling Removing the Chassis Cover and Protective Film Figure 6 2 1 Remove the two screws which secure the top cover onto the chassis as shown above 2 Lift the top cover up and off the chassis Figure 6 2 Removing the Chassis Cover Caution Except for short periods of time do NOT operate the server without the cover in place The chassis cover must be in place to allow proper airflow and prevent ove...

Страница 68: ...ouds one in each serverboard drawer p n MCP 310 21704 0B See the illustration below Installing an Air Shroud 1 Confirm that all four fans are in place and are working properly 2 Place the first air shroud into the serverboard drawer The air shroud sits behind the system fans and goes over the top of the serverboard and its components 3 Repeat the procedure for the remaining three serverboard drawe...

Страница 69: ...hassis internal temperature The SC827HQ system fans are hot swappable There is no need to power down the system when replacing fans and new tools are required for installation Optional Fan Configurations The SC827HQ model chassis is designed so that the default configuration of the system is for each serverboard to control two fans Figure 6 4 The fans are hot swappable Each serverboard node in the...

Страница 70: ...housing up and out of the chassis 4 Push the fan up from the bottom and out of the top of the housing 5 Place the replacement fan into the vacant space in the housing while making sure the arrows on the top of the fan indicating air direction point in the same direction as the arrows on the other fans 6 Put the fan back into the chassis and reconnect the cable see Figure 6 4 and Figure 6 5 for det...

Страница 71: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 5 Replacing a System Fan in the Fan Housing ...

Страница 72: ... Backplane Removing the Backplane from the Chassis 1 Power down and unplug the system from any power source 2 Remove the chassis cover 3 Disconnect the cabling to the backplane 4 Remove all of the hard drive trays from the front of the chassis 5 Remove the four upper screws at the top of the backplane indicated by the arrows below 6 Loosen the three screws in the spring bar located on the floor of...

Страница 73: ... side screw from the side of the chassis Figure 6 7 8 Gently ease the backplane up and out of the chassis Figure 6 8 Figure 6 7 Loosening the Spring Bar Screws in the Floor of the Chassis Figure 6 8 Removing the Backplane from the Chassis 1 7 1 6 1 8 ...

Страница 74: ...rovided 3 Slide the backplane into the chassis at a slight angle pushing it up against the side of the chassis 4 Ease the backplane forward against the front of the chassis This will aid in the alignment of the mounting holes 5 Align the mounting holes in the backplane with the holes in the chassis Replace the four screws at the top of the backplane and the screw on the side of the chassis 6 Adjus...

Страница 75: ...t rounded side up Depending upon the configuration of the serverboard being used it is also possible that some of the optional standoffs which are pre installed in the chassis may need to be removed Installing the Serverboard Figure 6 10 1 Review the documentation that came with your serverboard Become familiar with component placement requirements precautions and cable connections 2 Pull the serv...

Страница 76: ...erverboard backplane chassis front panel and power supply as needed Also fans may be temporarily removed to allow access to the backplane ports 9 Replace the add on card bracket and secure the bracket with a screw Figure 6 10 Installing the Serverboard in the Serverboard Node Drawer ...

Страница 77: ...rboard from the serverboard drawer by removing the screws securing it to the drawer Set the screws aside for later use 4 Remove the five screws securing the adapter card to the drawer and set them aside for later use 5 Remove the adapter card from the serverboard drawer Installing the Adapter Card Figure 6 11 1 Place the adapter card in the serverboard drawer aligning the holes in the adapter card...

Страница 78: ...e add on card slot clip in the rear of the chassis 3 Slide the temporary PCI slot shield toward the slot clip and remove the temporary shield from the chassis 4 Connect the add on card to the riser card 5 Secure the riser card to the serverboard tray using the riser card screw 6 Slide the add on card bracket into the rear add on card slot and secure with the add on card bracket screws 7 Close the ...

Страница 79: ...uals The SC827HQ chassis contains four individual serverboards in separate node drawers Figure 6 13 Each serverboard node controls a set of three hard drives Note that if a serverboard node drawer is pulled out of the chassis the hard drives associated with that node will power down as well Serverboard Drawer Locations in the Chassis Serverboard B Controls HDDs B1 B2 and B3 Serverboard D Controls ...

Страница 80: ...r s Manual Removing Hard Drive Trays from the Chassis Figure 6 14 1 Press the release button on the drive tray This extends the drive bay handle 2 Use the handle to pull the drive out of the chassis Figure 6 14 Removing Hard Drive 1 1 1 2 ...

Страница 81: ...for the drive bays Figure 6 15 Chassis Drive Tray Figure 6 16 Removing Dummy Drive from Tray Drive Tray Dummy Drive 1 1 1 1 Caution Except for short periods of time while swapping hard drives do not operate the server with the hard drives empty Installing a Drive into the Hard Drive Tray 1 Remove the screws holding connecting the drive tray the carrier Figure 6 16 2 Remove the tray from the carrie...

Страница 82: ...rive by tightening all six 6 screws 3 Use the open handle to replace the drive tray into the chassis Make sure the close the drive tray handle Figure 6 17 Installing the Hard Drive Drive Tray SATA Hard Drive 1 2 2 2 Caution Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers For information on recommended HDDs visit the Supermicro website at http www supermi...

Страница 83: ...er supply unit needs to be replaced one power supply can be removed without powering down the system Replacement units can be ordered directly from Supermicro See the contact information in the Preface of this manual Changing the Power Supply Figure 6 18 1 Power down all four nodes and unplug the power cord 2 Push the release tab on the back of the power supply as illustrated 3 Pull the power supp...

Страница 84: ...6 20 SUPERSERVER 5028TK HTR HTTR User s Manual Release Tab Figure 6 18 Changing the Power Supply ...

Страница 85: ... Each main BIOS menu option is described in this manual The AMI BIOS setup menu screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame...

Страница 86: ... only visible Power On Self Test POST routine is the memory test As the memory is being tested press the Delete key to enter the main menu of the AMI BIOS setup utility From the main menu you can access the other setup screens An AMI BIOS identification string is displayed at the left bottom corner of the screen below the copyright message Warning Do not upgrade the BIOS unless your system has a B...

Страница 87: ... Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in Day MM DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 Supermicro K1SPi T BIOS Version This item displays the version of the BIOS RO...

Страница 88: ...o select the screen display between POST messages or the OEM logo at bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST messages The options are Enabled and Disabled AddOn ROM Display Mode Use this item to set the display mode for the AddOn ROM messages Select Keep Current to use the current AddOn ROM Messages display setting Selec...

Страница 89: ... allow the BIOS to automatically reboot the system from a Legacy boot device after its initial boot failure The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function Select Enabled to allow the Watch Dog timer to reboot the system when it is inac tive for more than 5 minutes The options are Enabled and Disabled Power Button Function This feature controls how the syst...

Страница 90: ...o use address range monitor and advanced power management which will require the use of monitor instructions to enhance processor performance The options are Enable and Disable Execute Disable Bit Available if supported by the OS the CPU Select Enable for Execute Disable Bit Technology support which will allow the processor to designate areas in the system memory where an application code can exec...

Страница 91: ...Available when supported by the CPU Based on Intel s Hyper Threading architecture each logical processor thread is assigned 256 APIC IDs APIDs in 8 bit bandwidth When this feature is set to En able the APIC ID will be expanded X2 from 8 bits to 16 bits to provide 512 APIDs to each thread to enhance CPU performance The options are Enable and Disable AES NI Select Enable to use the Intel Advanced En...

Страница 92: ...set to Enable the following items will display Config TDP Level Available when Config TDP above is set to Enable Use this item to set TDP configuration level to enhance thermal management The options are Nominal Level 1 and Level 2 CPU P State Control P state Domain Use this feature to select the domain type for the P state Power Performance State If Per Package is selected all processors on the m...

Страница 93: ...bled to use the Turbo Mode to boost system performance The options are Enable and Disable CPU C State Control CPU C State Select Enable to enable CPU C State support to enhance CPU power management Please reboot the system for the change of the setting to take effect The options are Disable and Enable Package C State limit Use this item to set the limit on the C State package register The options ...

Страница 94: ... Enable Long Term Pwr Power Limit Ovrd Override Select Enable to support long term power limit override If this feature is set to Disabled BIOS will set the default value The options are Enable and Disable Long Duration Pwr Power Limit Select Enable to set the power limit during which the TDP Thermal Design Power value should be maintained The default setting is 0 Long Duration Time Window Select ...

Страница 95: ... to enable this feature to maximize the reliability of the A 0 Silicon when the IIO is strapped for Wait for BIOS The options are Yes and No EV DFX Device Function On Hide Features When this feature is set to Enable EV_DFX Lock Bits that are located on a processor will always remain clear during electric tuning The options are Dis able and Enable IIO0 Configuration IOU2 II0 PCIe Port 1 This item c...

Страница 96: ...e the transition from L0s to L0 The default setting is 4uS 8uS PCI E Port L1 Exit Latency Use this feature to set the length of time required for the port specified by the user to complete the transition from L1 to L0 The options are 1uS 1uS 2uS 2uS 4uS 4uS 8uS 8uS 16uS 16uS 32uS 32uS 64uS and 64uS Fatal Err Error Over Select Enable to force a fatal error that has occurred to the port specified by...

Страница 97: ...tion Power Interface ACPI support for the IO device specified by the user The options are Enable and Disable Intel VT for Directed I O VT d Intel VT for Direct I O VT d PCI Express Global Options The section allows the user to configure the following PCI E global options WA 4167453 Select Enable for WA 4167453 support The options are Disable and Enable NoSnoop No Snoop Config Configuration Use thi...

Страница 98: ...orting the I O device assignments to the VMM Virtual Machine Monitor through the DMAR ACPI tables This feature offers fully protected I O resource sharing across Intel platforms providing greater reliability security and availability in networking and data sharing The options are Enable and Disable ACS Control This item determines how to use the Access Control Service ACS in the sys tem ACS contro...

Страница 99: ...for regular use and for cache use Select Auto to allow the BIOS automatically configure the MCDRAMs for the function specified by the BIOS The options are Flat Cache Hybrid and Auto Treat MCDRAM as Hot Pluggable Memory Available when the Memory Mode above is set to Flat or Hybrid If this feature is set to Yes the MCDRAM will be treated as a Hot Pluggable de vice which can be changed or re configur...

Страница 100: ... data updates The op tions are Diable Store Use and UseStorre EDC Demand Scrub Demand Scrubbing is a process that allows the CPU to correct correctable memory errors found on the EDC When the CPU or I O issues a demand read command and the read data from memory turns out to be a correctable error the error is corrected and sent to the requestor the original source Memory is updated as well Select ...

Страница 101: ... Enabled and Disabled Data Scrambling Select Enabled for data scrambling support to enhance system security and data integrity The options are Enabled and Disabled Memory Information This item displays the information of a DIMM module as detected by the AMI BIOS The following items will display DIMMA1 DIMMB1 DIMMC1 DIMMD1 DIMME1 DIMMF1 Memory Map Memory Map Channel Interleaving Use this item to se...

Страница 102: ...e next complete patrol scrub is performed Use the keyboard to enter a value from 0 24 The Default setting is 24 Demand Scrub Demand Scrubbing is a process that allows the CPU to correct correctable memory errors found on a memory module When the CPU or I O issues a demand read command and the read data from memory turns out to be a correctable error the error is corrected and sent to the requestor...

Страница 103: ... Hand Off This item is for operating systems that do not support Enhanced Host Controller Interface EHCI hand off When this item is enabled EHCI ownership change will be claimed by the EHCI driver The settings are Enabled and Disabled Port 60 64 Emulation Select Enabled to support I O port 60h 64h emulation which will provide complete legacy USB keyboard support for the operating systems that do n...

Страница 104: ...ages the power usage of the SATA link The controller will put the link to a low power state when the I O is inactive for an extended period of time and the power state will return to normal when the I O becomes active The options are Enabled and Disabled SATA Port 0 Port 5 This item displays the information detected on the installed SATA drive on the particular SATA port Model number of drive and ...

Страница 105: ...rive and capacity Software Preserve Support Port 0 Port 5 SATA Device Type Available when a SATA port is detected Use this item to specify if the SATA port specified by the user should be con nected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Solid State Drive If the item above Configure SATA as is set to RAID the following items will display SATA RSTe Boot Info...

Страница 106: ...plays the following items sSATA Controller This item enables or disables the onboard sSATA controller The options are En abled and Disabled Configure sSATA as Select IDE to configure an sSATA drive specified by the user as an IDE drive Select AHCI to configure an sSATA drive specified by the user as an AHCI drive Select RAID to configure an sSATA drive specified by the user as a RAID drive The op ...

Страница 107: ...nitialization to the device The options are Enabled and Disabled Port 0 Port 5 sSATA Device Type Use this item to specify if the sSATA port specified by the user should be con nected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Solid State Drive If the item above Configure sSATA as is set to IDE the following items will display Aggressive Link Power Management Wh...

Страница 108: ...0 Port 5 This item displays the information detected on the sSATA drive connected to the particular sSATA port specified by the user Model number of drive and capacity Software Preserve Support sSATA Port 0 Port 5 Select Enabled to enable a SATA port specified by the user The options are Dis abled and Enabled Port 0 Port 5 Hot Plug Select Enabled to enable hot plugging support for a port specified...

Страница 109: ...Timer Use this item to configure the PCI latency timer for a device installed on a PCI bus Select 32 to set the PCI latency timer to 32 PCI clock cycles The options are 32 64 96 128 160 192 224 and 248 PCI Bus Clocks PCI X Latency Timer Use this item to configure the PCI X latency timer for a device installed on a PCI X bus Select 32 to set the PCI latency timer to 32 PCI clock cycles The options ...

Страница 110: ...1024 Bytes 2048 Bytes and 4096 Bytes MMIOHBase Use this item to select the I O base memory size according to memory address mapping for the PCH chip The base memory size must be between 4032G to 4078G The options are 56T 48T 24T 512G and 256G SXB1 PCI E x16 OPROM SXB2 PCI E x4 OPROM SXB3 PCI E x16 OPROM Select Enabled to enable Option ROM support to boot the computer using a de vice installed on t...

Страница 111: ...t 1 Serial Port 2 Select Enabled to enable the onboard serial port specified by the user The options are Enabled and Disabled Device Settings This item displays the base I O port address and the Interrupt Request address of a serial port specified by the user Change Port 1 Settings Change Port 2 Settings This feature specifies the base I O port address and the Interrupt Request address of Serial P...

Страница 112: ...n Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 38400 57600 and 115200 bits per second Data Bits Use this item to set the data transmission size for Console Redirection The options are 7 Bits and 8 Bits Parity A parity bit can be sent along with reg...

Страница 113: ...egacy OS Redirection Resolution Use this item to select the number of rows and columns used in Console Redi rection for legacy OS support The options are 80x24 and 80x25 Putty KeyPad Use this item to select Function Keys and KeyPad settings for Putty which is a terminal emulator designed for the Windows OS The options are VT100 LINUX XTERMR6 SCO ESCN and VT400 Redirection After BIOS Post Use this ...

Страница 114: ... set the data transmission size for Console Redirection The options are 7 Bits and 8 Bits Parity A parity bit can be sent along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the number of 1 s in data bits is odd Select None if you do not want to send a parit...

Страница 115: ...l emulator designed for the Windows OS The options are VT100 LINUX XTERMR6 SCO ESCN and VT400 Redirection After BIOS Post Use this feature to enable or disable legacy Console Redirection after BIOS POST Power On Self Test When this feature is set to Bootloader legacy Console Redirection is disabled before booting the OS When this feature is set to Always Enable legacy Console Redirection remains e...

Страница 116: ... key support Select ANSI to use the extended ASCII character set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The options are ANSI VT100 VT100 and VT UTF8 Bits Per Second This item sets the transmission speed for a serial port used in Console Redirec tion Make sure that the same speed is used in both host computer and the client computer A lower transmission...

Страница 117: ... the Advanced tab From there navigate down and select the CPU Configuration option as shown below Press Enter 3 You will be taken to the CPU Configuration page Using the arrow keys navi gate down to the Intel Virtualization Technology option and press Enter Select Enable and press Enter 4 Once you have enabled Virtualization support press your Esc key until you are back to the Advanced tab Navigat...

Страница 118: ...itoring The options are Enabled and Disabled High Precision Event Timer Select Enabled to activate the High Precision Event Timer HPET that produces periodic interrupts at a much higher frequency than a Real time Clock RTC does in synchronizing multimedia streams providing smooth playback and reducing the de pendency on other timestamp calculation devices such as an x86 RDTSC Instruc tion embedded...

Страница 119: ...tion information iSCSI Initiator Name Use this item to enter the name of the iSCSI Initiator which is a unique name used in the world The name must in the IQN format The following submenu will be available for configuration Add an Attempt Delete Attempts Change Attempt Order ...

Страница 120: ...BIOS Event Log Select Enabled to enable SMBIOS System Management BIOS Event Logging during system boot The options are Enabled and Disabled Runtime Error Logging Support Select Enable to support Runtime Error Logging The options are Enable and Disable Erasing Settings Erase Event Log Select Yes to erase all error events in the SMBIOS System Management BIOS log before an event logging is initialize...

Страница 121: ...nt Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This item is used to determine how long in minutes the multiple event counter should wait before generating a new event log Enter a number between 0 to 99 The default setting is 60 Note Please reboot the system for the changes to take effect Cus...

Страница 122: ...PMI firmware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled to enable all system event logging support at bootup The options are Enabled and Disabled Erasing Settings Erase SEL Select Yes On next reset to erase all system event logs upon next system reboot Select Yes On every reset to erase all system event logs upon each system reboot Select No ...

Страница 123: ...s set to Yes Use this item to select the IP address source for this computer If Static is selected you will need to know the IP address of this computer and enter it to the system manually in the field If DHCP is selected AMI BIOS will search for a DHCP Dy namic Host Configuration Protocol server attached to the network and request the next available IP address for this computer The options are DH...

Страница 124: ... the BIOS Setup utility The options are Setup and Always Administrator Password Use this feature to set the administrator password which is required before entering the BIOS setup utility The length of the password should be from 3 characters to 20 characters long User Password Use this feature to set the user password which is required to enter the BIOS setup utility The length of the password sh...

Страница 125: ... Default Keys Select Enable to install all manufacturer default keys for the following system se curity settings The options are Disabled and Enabled Enroll All Factor Default Keys Select Enable to install all manufacturer defaults for the following system security settings The options are Yes and No Save All Secure Boot Variables This feature allows the user to set and save the following Secure B...

Страница 126: ...This feature allows the user to set and save the forbidden signatures and deny the access to those whose names appear on the list Authorized TimeStamps This feature allows the user to set and save the timestamps for authorized signa tures to indicate when these signatures were entered into the system OsRecovery Signatures This feature allows the user to set and save the authorized signatures used ...

Страница 127: ...which the system will boot Press Enter on each entry from top to bottom to select devices When the item above Boot Mode Select is set to Dual default the following items will be displayed for configuration Dual Boot Order 1 Boot Order 15 When the item above Boot Mode Select is set to Legacy the following items will be display for configuration Legacy Boot Order 1 Boot Order 7 When the item above B...

Страница 128: ...n File Path Use this feature to set a new driver file path for boot option Create Use this feature to create a new boot option for the new driver Delete Driver Option Use this item to select a boot driver to delete from the boot priority list Delete Drive Option Select the target boot driver to delete from the boot priority list Hard Disk Drive BBS Priorities Legacy Boot Order 1 Network Drive BBS ...

Страница 129: ...save the changes you ve made and then reboot the computer for the new system con figuration changes to take effect Save Options Save Changes After you have made all changes on the BIOS settings select this option to save all changes made This will not reset reboot the system Discard Changes Select this option and press Enter to discard all the changes you ve made and return to the AMI BIOS setup u...

Страница 130: ...ettings for future use Restore User Defaults Select this item and press Enter to retrieve user defined settings that were previ ously saved for future use Boot Override This feature allows the user to override the Boot priorities sequence in the Boot menu and immediately boot the system with another device specified by the user This is a one time override ...

Страница 131: ...GB of RDIMM Registered DIMM DDR4 2400 ECC memory Note refer to Section 5 5 for details on installation and the Supermicro website for the latest memory support information SATA Drive Bays Twelve hot swap drive bays to house 3 5 SATA drives PCI Expansion Each node in the system can accommodate two PCI E 3 0 x16 expansion cards Serverboard K1SPi K1SPi T serverboard proprietary form factor Dimensions...

Страница 132: ...40º to 158º F Operating Relative Humidity 20 to 95 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class A EN 55022 Class A EN 61000 3 2 3 3 CISPR 22 Class A Electromagnetic Immunity EN 55024 CISPR 24 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Comp...

Страница 133: ...B 3 Appendix A System Specifications Notes ...

Страница 134: ...o perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in such ultra hazardous applications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and all ...

Страница 135: ...ter system at bootup B 2 Recovering the UEFI BIOS Image Main BIOS Block A UEFI BIOS flash chip consists of a recovery BIOS block which is comprised of two boot blocks and a main BIOS block the main BIOS image The boot block contains critical BIOS codes including memory detection and recovery codes for the user to flash a new BIOS image if the original main BIOS image is corrupted When the system p...

Страница 136: ...powering on the system keep pressing Ctrl and Home simultane ously on your keyboard until your hear two short beeps This may take from a few seconds to one minute 4 After locating the new BIOS binary image the system will enter the BIOS recovery menu as shown below Note At this point you may decide if you want to start with BIOS Recovery If you decide to proceed with BIOS Recovery follow the proce...

Страница 137: ... has completed press any key to reboot the system 7 Using a different system extract the BIOS package into a bootable USB flash drive 8 When the DOS prompt appears enter AMI BAT BIOSname Note Do not interrupt this process until BIOS flashing has completed ...

Страница 138: ...power cable from the power supply to clear CMOS then plug the AC power cable in the power supply again to power on the system 10 Press Del continuously to enter the BIOS Setup utility 11 Press F3 to load the default settings 12 After loading the default settings press F4 to save the settings and exit the BIOS Setup utility ...

Отзывы: